Review
The ACiQ 5-ton system positions itself as a mid-market replacement for aging furnace-AC combinations. Manufactured under the Goodman umbrella, this unit combines a 92% AFUE gas furnace with a 14 SEER1 air conditioning condenser in an upflow configuration. The system ships as an integrated package, reducing installation complexity compared to separate components. At this price point and efficiency tier, it competes directly with other direct-comfort and budget-focused brands targeting contractors who prioritize value without cutting corners on proven technology.
Heating performance delivers 47,000 BTU output with a single-stage burner burning natural gas on 208/230V single-phase power. Cooling operates at 46,000 BTU with a scroll compressor and single-stage condenser, yielding the 14 SEER1 rating. The multi-speed blower motor can push up to 2,000 CFM, enabling the system to serve homes between 1,200 and 1,800 square feet effectively. Energy Star certification confirms this unit meets EPA efficiency thresholds, qualifying buyers for available rebates in many states. The 74 dB noise level keeps operation relatively quiet during heating cycles.
Pros & Cons
Pros
- 92% AFUE furnace efficiency significantly reduces winter heating costs compared to 80% baseline units
- 14 SEER1 cooling rating qualifies for Energy Star, supporting federal and state rebates
- Multi-speed blower motor improves comfort by reducing temperature swings and improving air distribution
- Scroll compressor is known for durability and quiet operation at 74 dB
- PVC exhaust flue allows flexible ductwork routing, simplifying attic or basement installations
Cons
- Single-stage burner and single-stage compressor mean less precise comfort control than two-stage systems
- R454B refrigerant availability is still limited compared to R410A, potentially complicating future service
- Heating capacity of 47,000 BTU falls short for homes over 1,500 square feet in cold climates requiring supplemental heat
- Cooling output of 46,000 BTU is undersized for the claimed 5-ton rating, creating a capacity mismatch
Who Should Buy
Best For
Homeowners in mild to moderate climates replacing older 80-85% AFUE furnaces who want integrated heating and cooling in one unit. Contractors installing all-in-one systems in new construction or major renovations where space is limited and rebate incentives are available.
Consider Alternatives If
Anyone in severe winter climates needing maximum heating capacity, or buyers seeking two-stage compressors for superior humidity and temperature control should explore alternatives.
Installation
This upflow/downflow configuration accepts plastic PVC exhaust flue venting, reducing installation costs versus metal options. Requires 208/230V single-phase 60 Hz power with breaker capacity between 26.4 and 40 amps. Dimensions of 30 inches tall by 24.5 inches wide by 21 inches deep fit standard utility closets and attic spaces. Technicians need standard EPA 608 refrigerant certification for R454B handling. A-coil design uses 3/8-inch liquid lines and 1 1/8-inch suction lines with 1/2-inch insulation thickness.
Warranty & Reliability
ACiQ provides a 10-year parts warranty when you register online within 30 days of purchase. This covers the furnace, compressor, and coil against manufacturing defects. Registration is straightforward and typically takes five minutes on their website. No labor coverage is included, so service calls beyond the parts warranty remain your responsibility. This warranty is solid for the price tier but trails premium brands offering 12-year coverage.
Specifications
| SKU | ACIQ-48-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 46,000 |
| Heating BTU | 47,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 92% |
| Blower Motor | Multi Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Single |
| Fuel Type | Gas |
| Height | 30" |
| Width | 24.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Replaces | GSZ140491 |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 40 amps |
| Min. Breaker Size | 26.4 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions