Independent Review · Updated June 2026

Goodman 4 Ton 14 SEER 96% 120,000 BTU Furnace & AC System - R410A Downflow

High-efficiency gas furnace with solid cooling, Energy Star certified and ready to install

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
Goodman 4 Ton 14 SEER 96% 120,000 BTU Furnace & AC System - R410A Downflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ system is best for homeowners upgrading from older 13 SEER units who want modern efficiency without premium pricing. The 96% AFUE furnace and 14 SEER cooling make it a smart choice for cold climates where heating dominates energy costs.

Review

The Goodman 4 Ton 14 SEER 96% Furnace and AC System represents solid mid-market equipment from ACiQ, a budget-friendly brand trusted by regional contractors. This downflow configuration works well for homes with basement or attic mechanical rooms requiring horizontal discharge. The system combines gas furnace heating with air conditioning in one package, simplifying installation for replacement jobs where existing ductwork is in place.

Heating performance delivers 47,000 BTU per hour with 96% AFUE efficiency, converting nearly all fuel to usable heat. Cooling capacity reaches 46,000 BTU at 14 SEER, qualifying for Energy Star designation. The scroll compressor runs single-stage only, meaning it cycles on and off rather than modulating capacity. Multi-speed blower reaches 2,000 CFM maximum, providing flexibility for different duct designs and room sizes.

Pros & Cons

Pros

  • 96% AFUE furnace efficiency significantly reduces heating fuel consumption and monthly gas bills
  • 14 SEER cooling rating qualifies for Energy Star certification and many utility rebates
  • Compact dimensions (30" H x 24.5" W x 21" D) fit tight mechanical closets and attic spaces
  • Multi-speed blower motor allows fine-tuned airflow and better comfort control
  • PVC exhaust compatible with modern condensing furnace venting requirements
  • 10-year warranty with online registration provides solid long-term protection

Cons

  • Single-stage burner and compressor limit efficiency gains compared to two-stage alternatives
  • 74 dB noise level runs slightly louder than premium models, noticeable in quiet homes
  • R454B refrigerant requires updated technician certification, limiting service options in some areas
  • 5-ton tonnage may oversized for moderate climates, reducing efficiency benefits

Who Should Buy

Best For

Contractors installing replacements in homes with existing ductwork for 4-5 ton systems, especially in northern climates where heating load justifies the investment. Budget-conscious homeowners seeking Energy Star efficiency without stepping up to premium variable-stage equipment.

Consider Alternatives If

Homeowners in mild climates where cooling dominates, or those prioritizing ultra-quiet operation should explore higher SEER models with variable-speed compressors.

Goodman 4 Ton 14 SEER 96% 120,000 BTU Furnace & AC
$0
Buy at HVACDirect →

Installation

Downflow configuration requires vertical clearance above the unit and ductwork routing below. Needs 208-230V single-phase electrical service with 26.4 to 40-amp breaker capacity. PVC flue venting connects to the right side, requiring plastic piping to roof or wall termination. Standard installation takes 6-8 hours for experienced crews, longer if new refrigerant lines exceed 50 feet.

Warranty & Reliability

10-year parts warranty activates through online registration after purchase. Covers compressor, heat exchanger, and most components against defects. Labor and refrigerant are excluded. Registration is essential, as implied warranty applies without it. Coverage period is strong for mid-tier equipment at this price point.

Specifications

SKUACIQ-48-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU46,000
Heating BTU47,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)120.000000
FeatureSpec
Airflow DirectionDownflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE96%
Blower MotorMulti Speed
Maximum CFM2000
ConfigurationUpflow / Downflow
Flue LocationRight
Burner StagesSingle
Fuel TypeGas
Height30"
Width24.5"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ReplacesGSZ140491
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Max Breaker Size40 amps
Min. Breaker Size26.4 amps
Tonnage5 Ton
Valve TypeSweat
Liquid Line3/8"
Suction Line1 1/8"
StyleA-Coil
Suction Line Insulation Thickness1/2"
Length50 feet

Frequently Asked Questions

Does this unit work in downflow and upflow orientations? +
The spec sheet lists configurable downflow/upflow, but this listing emphasizes downflow with right-side flue exit. Verify with your contractor whether your installation allows upflow conversion. Flue position may limit upflow viability in some applications.
What electrical service do I need to install this system? +
Requires 208V or 230V single-phase 60Hz power with minimum 26.4-amp breaker and maximum 40-amp breaker capacity. Most residential homes use 230V service. A licensed electrician should verify your panel capacity before ordering.
How does 14 SEER compare to modern equipment? +
14 SEER meets Energy Star standards but ranks mid-tier today. Two-stage or variable-speed systems reach 15-18 SEER. This unit performs well for replacements from 13 SEER age equipment, typically saving 7-10% on annual cooling costs.
Why does the spec sheet show both 4-ton and 5-ton ratings? +
Product name states 4 ton, but specs list 5-ton tonnage, likely a documentation error. Verify actual capacity with the seller before purchasing. This discrepancy warrants clarification to ensure proper home sizing.
Is online warranty registration required? +
Yes. The 10-year coverage requires online registration. Without registration, you lose extended warranty protection. Complete registration immediately after installation to activate full coverage.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.