Review
The ACiQ ACIQ-48-EHPD-UPG represents a straightforward, competent solution for residential HVAC replacement. This 4-ton upflow system combines a gas furnace and air conditioner in one package, eliminating the complexity of sourcing matched components separately. It's positioned as a mid-tier option, lacking premium features like inverter-driven compressors but offering solid fundamental performance at reasonable cost. ACiQ manufacturers equipment under parent company Goodman, ensuring manufacturing standards and supply chain reliability that contractors depend on.
Performance numbers tell the real story here. The furnace delivers 80,000 BTU output at 96% AFUE, meaning 96 cents of every natural gas dollar converts to usable heat, the legal maximum for non-condensing units. The air conditioner provides 48,000 BTU cooling capacity with 13 SEER1 efficiency using R454B refrigerant. The variable-speed ECM blower motor runs from 0 to 1600 CFM, matching airflow to actual heating and cooling demands rather than running full blast constantly. Energy Star certification confirms independent verification of these efficiency claims.
Pros & Cons
Pros
- 96% AFUE furnace efficiency means lower winter heating bills and reduced natural gas waste
- 13 SEER cooling with R454B refrigerant meets current EPA standards without retrofit hassle
- Variable speed ECM blower motor adjusts airflow from 0 to 1600 CFM for comfort and efficiency
- PVC/plastic flue compatibility simplifies venting in many existing installations
- Two-stage burner reduces temperature swings and improves comfort over single-stage models
- Energy Star certified system qualifies for utility rebates in many regions
Cons
- Single-stage compressor in the air conditioner limits part-load efficiency compared to variable capacity units
- 76 dB noise level is audible during operation, noticeable in quiet homes
- 5-ton capacity mismatches the stated 4-ton rating, creating confusion during system sizing
Who Should Buy
Best For
Contractors installing matched furnace-condenser pairs for residential replacements in climate zones 3-5, and homeowners in moderate climates prioritizing heating efficiency without premium cooling capabilities. This system works best where heating season costs exceed cooling costs.
Consider Alternatives If
Anyone in hot climates needing multi-stage cooling, homes with very tight noise budgets, or builders planning premium installations where variable-capacity compressors justify higher costs.
Installation
The upflow configuration and compact 30x21x21 inch footprint fit standard utility closets and basement installations. PVC/plastic flue requirement simplifies venting compared to metal flue-dependent systems. Electrical demands are moderate, requiring 26.3 to 45 amp breaker sizing on standard 115V 1-phase 60Hz service. Sweat valve connections use standard 3/8 inch liquid and 1 1/8 inch suction lines with 1/2 inch insulation included for 50 feet of lineset.
Warranty & Reliability
Ten-year coverage applies when registered online within 30 days of installation, a standard practice across the industry. This warranty covers compressor, coil, and furnace heat exchanger failures. It does not cover routine maintenance, refrigerant recharges, or damage from improper installation. Online registration is free and takes five minutes, making this warranty accessible to both contractors and DIY-inclined homeowners.
Specifications
| SKU | ACIQ-48-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 48,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 76 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130483, GSX130484, GSX130485 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 26.3 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368835 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1600 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.