Review
This Goodman combination system represents a practical middle ground in the HVAC market, offering respectable efficiency without the premium price tag. The unit combines a 100,000 BTU furnace with a 48,000 BTU air conditioner in a standard upflow A-coil configuration. It's designed as a complete replacement for older Goodman models like the GSX130483-485 series. The system uses R454B refrigerant, aligning with current environmental standards and avoiding future regulatory headaches.
Performance specs tell the real story. The furnace delivers 96% AFUE efficiency through two-stage heating and a variable-speed ECM blower capable of 2000 CFM maximum airflow. The air conditioner achieves 13 SEER1 efficiency with a single-stage reciprocating compressor running on 115V, 60Hz power. The combination qualifies for ENERGY STAR certification, translating to roughly 4-8% annual heating cost savings versus 90% AFUE equipment. Cooling noise runs 76 dB, which is moderate and noticeable but not unusually loud for this tonnage class.
Pros & Cons
Pros
- 96% AFUE furnace efficiency means heating costs 4-8% lower than 90% AFUE competitors
- 13 SEER air conditioner qualifies for ENERGY STAR and many utility rebates
- Two-stage heating and variable-speed ECM blower provide comfort and quiet operation
- R454B refrigerant meets current EPA standards with no future phase-out concerns
- Lifetime heat exchanger warranty covers the most expensive potential failure point
Cons
- Single-stage compressor limits cooling efficiency compared to two-stage models at 14+ SEER
- 76 dB noise level is louder than premium units, noticeable during compressor operation
- 5-ton outdoor condenser paired with 4-ton furnace creates minor AHRI mismatch requiring careful ductwork planning
Who Should Buy
Best For
Homeowners replacing 15+ year old systems in moderate to cold climates who prioritize heating efficiency and want EPA rebate eligibility. Contractors seeking reliable, mid-tier equipment with straightforward installation and proven Goodman reliability.
Consider Alternatives If
Buyers in hot climates seeking maximum AC efficiency, or those with tight acoustic requirements who can't tolerate 76 dB operation.
Installation
Installation complexity ranks moderate. The unit requires 3/8-inch liquid lines and 1 1/8-inch suction lines with 1/2-inch insulation, both sweat connections. Electrical demands fall within standard 200-amp residential service (26.3 to 45 amp breaker range). PVC exhaust flue compatibility simplifies gas venting. The 34.5-inch height and 21-inch width fit most closets and utility rooms. Professional installation strongly recommended for refrigerant handling and ductwork integration.
Warranty & Reliability
Coverage includes a lifetime heat exchanger warranty and 10 years parts protection with online registration. The heat exchanger lifetime coverage is valuable because heat exchanger replacement typically costs 40-60% of total system price. The 10-year parts warranty requires registration but covers compressor, blower motor, and control boards. Labor is not included, so extended service plans from local contractors provide additional cost protection.
Specifications
| SKU | ACIQ-48-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 48,000 |
| Heating BTU | 100,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 76 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130483, GSX130484, GSX130485 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 26.3 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 21" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7368836 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions