4 Ton 17.5 SEER 96% AFUE 120,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This Goodman system is ideal for homeowners replacing older split systems in moderate climates who prioritize fuel efficiency and want reliable performance without premium pricing. The 96% AFUE and 17.5 SEER1 deliver solid energy savings, though it's not the highest-tier option available.

Review

The Goodman CAPF4961D6 represents a solid midmarket choice for homeowners seeking dependable heating and cooling without flagship-tier specifications. This 4-ton upflow system pairs a 96% AFUE furnace with a 17.5 SEER1 air conditioner, delivering respectable efficiency across both seasons. Goodman's reputation for affordability and contractor support remains strong, though this particular model occupies the practical middle ground rather than pushing innovation boundaries.

Heating performance lands at 120,000 BTU output with two-stage burner control, while cooling reaches 47,000 BTU at 17.5 SEER1 with a scroll compressor and two-stage condenser. The variable-speed ECM blower handles up to 2,000 CFM, adapting airflow to actual demand rather than running at full power constantly. These specifications translate to reasonable monthly utility bills, particularly in moderate heating climates where the furnace efficiency advantage shows itself.

Pros & Cons

Pros

  • 96% AFUE furnace efficiency is excellent for gas heating, reducing fuel costs substantially compared to 80-85% systems
  • 17.5 SEER1 cooling efficiency qualifies for Energy Star, with two-stage compressor and variable-speed ECM blower for modulation
  • Two-stage burner and scroll compressor minimize cycling losses and extend component lifespan in most conditions
  • Compact A-coil design fits standard upflow and downflow installations with minimal ductwork modifications
  • 10-year warranty with online registration provides decent protection for major components without premium pricing

Cons

  • 17.5 SEER1 lags behind 18+ SEER systems from competitors, translating to slightly higher cooling costs in hot climates
  • 72 dB noise level is moderately loud during compressor operation, noticeable near outdoor condenser unit
  • Variable-speed blower requires 115V/60Hz power and 29.3-50 amp breaker, demanding clean electrical infrastructure

Who Should Buy

Best For

Homeowners in zones 4-6 replacing 15-20 year old furnace-AC combos who want measurable efficiency gains at mid-range pricing. This system suits those prioritizing heating performance with adequate cooling rather than maximum AC efficiency.

Consider Alternatives If

Buyers in extreme climates (Arizona, Florida) requiring maximum SEER ratings, or those with budget constraints where older Goodman models at lower price points make more sense.

4 Ton 17.5 SEER 96% AFUE 120,000 BTU Goodman Gas F
$0
Buy at HVACDirect →

Installation

Installation requires 115V single-phase 60Hz power with 29.3 to 50-amp breaker capacity, standard for most residential panels. The upflow A-coil configuration fits existing ducts without major rework on homes built after 1990. PVC/plastic exhaust venting accommodates modern condensing furnaces, though existing metal flues need replacement. Professional installation is essential for proper refrigerant charging and airflow balancing.

Warranty & Reliability

Goodman provides 10 years of parts coverage when you register online within 30 days of installation. This covers compressor, coil, and major components but excludes labor costs. Registration is straightforward through Goodman's website and protects your investment against manufacturing defects, though it's not a transferable warranty across homeowners.

Specifications

SKUCAPF4961D6
Brand/ManufacturerGoodman
Cooling BTU47,000
Heating BTU120,000
RefrigerantR410A or R22
Electrical115 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)72
Weight (in lbs)50.000000
FeatureSpec
Energy StarYes
SEER1 (Efficiency)18
Condenser StagesTwo Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Max Breaker Size50 amps
Min. Breaker Size29.3 amps
Tonnage5 Ton
Valve TypeSweat
Height30"
Width24.5"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
AHRI Certificate Number7368842
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Product FeaturesRebate Available
Furnace Efficiency / AFUE96%
Blower MotorVariable Speed - ECM
Maximum CFM2000
ConfigurationUpflow / Downflow
Burner StagesTwo
Fuel TypePropane, Natural Gas
Liquid Line3/8"
Suction Line7/8"
StyleA-Coil

Frequently Asked Questions

How does 17.5 SEER1 compare to other systems in this price range? +
17.5 SEER1 is solid mid-tier efficiency. Higher-end Goodman and competing brands reach 18-20 SEER1, cutting cooling costs 5-10% more annually. For moderate climates, this gap costs roughly $50-100 per year. The trade-off makes sense if upfront budget is tight.
Will this furnace work with my existing ductwork? +
Likely yes if your home has standard forced-air ducts. The upflow A-coil design fits most installations built after 1990. Have a technician verify duct sizing matches the 2,000 CFM maximum airflow. Undersized ducts reduce efficiency and comfort significantly.
What refrigerant does this unit use, and does it matter? +
This unit accepts R410A or R22 depending on the coil paired with it. R410A is standard for new systems and widely available. R22 is obsolete, more expensive, and being phased out. Always specify R410A with new installations to avoid future supply and cost issues.
Is Goodman reliable compared to Carrier or Lennox? +
Goodman equipment performs comparably to Carrier mid-tier units at lower cost. Independent repair data shows similar failure rates across 5-10 years. Goodman's value proposition is price, not premium durability. All require professional installation and maintenance for longevity.
Does online registration actually protect me if something breaks? +
Yes, but only for defects, not wear items or installer errors. Register within 30 days or lose coverage. Keep your receipt and registration proof. Labor costs fall on you, so factor service plan costs into total ownership expenses.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.