Review
The 5-ton Goodman system represents a practical middle ground in residential HVAC equipment. Priced at $2,053, it targets cost-conscious homeowners and contractors managing budget constraints while still demanding solid baseline performance. Goodman's reputation for manufacturing straightforward, serviceable equipment carries weight among technicians, though the brand rarely leads the efficiency charts. This upflow configuration suits typical residential installations in attics or closets where space and ducting favor vertical mounting.
Performance metrics show a 13 SEER cooling rating paired with 60,000 BTU capacity and an 80,000 BTU heating output at 80% AFUE. The variable-speed blower motor maximizes comfort by modulating CFM up to 2,000, while the two-stage burner provides heating flexibility. However, the single-stage reciprocating compressor operates at full capacity regardless of outdoor temperature, missing efficiency gains available with modulating designs. The 77 dB noise level is noticeable but typical for this equipment class and price tier.
Pros & Cons
Pros
- 13 SEER rating keeps summer cooling costs reasonable for a mid-range unit, qualifying for some regional rebates
- 80,000 BTU heating capacity handles cold winters in most temperate zones without undersizing issues
- Variable speed blower motor optimizes comfort by adjusting airflow based on demand, reducing temperature swings
- Two-stage burner modulates heating output for better efficiency and comfort during mild weather
- 10-year warranty with online registration covers parts and labor, protecting your $2,053 investment
- R410A refrigerant is widely available and compatible with modern HVAC infrastructure
Cons
- 80% AFUE is respectable but trails newer 95%+ AFUE systems, meaning higher heating bills over time
- Single-stage condenser cannot modulate cooling capacity, running at full power even on mild days
- Not Energy Star certified, indicating efficiency sits at baseline rather than premium levels
- 77 dB noise level is audible from nearby windows, higher than quieter premium models
- Reciprocating compressor is noisier and less efficient than newer scroll or variable-displacement designs
Who Should Buy
Best For
Homeowners replacing failed 10-15 year old systems who prioritize affordability over cutting-edge efficiency and live in moderate climates where single-stage operation is acceptable. Contractors seeking reliable equipment for rental properties or price-sensitive residential projects will appreciate the straightforward design and broad compatibility.
Consider Alternatives If
Buyers in extremely cold climates needing maximum heating efficiency, those seeking Energy Star certification for tax credits, or homeowners willing to invest more upfront for lower lifetime operating costs should explore 16+ SEER and 90%+ AFUE alternatives.
Installation
Installation demands standard skills for upflow configurations with A-coil design. The unit requires 120V single-phase 60 Hz power, needing 32.8 to 45 amp breaker capacity for safe operation. Refrigerant lines use 3/8 inch liquid and 7/8 inch suction connections with sweat-type valves. Metal exhaust flue is mandatory for the gas furnace section. Dimensions of 34.5 inches tall, 21 inches wide, and 28.75 inches deep fit most standard return air plenums without major modifications.
Warranty & Reliability
Goodman provides a 10-year parts and labor warranty when you complete online registration after purchase. This coverage protects compressor, heat exchanger, and coil failures, offering reasonable peace of mind for residential use. Labor coverage is valuable since HVAC service calls typically run $150 to $300. Keep documentation organized and ensure the technician registers the unit promptly to activate full coverage.
Specifications
| SKU | LS38783830 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 60,000 |
| Heating BTU | 80,000 |
| Refrigerant | R410A |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 77 |
| Weight (in lbs) | 30.000000 |
| Feature | Spec |
| Replaces | GSX130603, GSX130604, GSX130605, GSX130611, GSX130613, GSX130614 |
| Energy Star | No |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 21" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 204633302 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.