Review
The ACiQ 5-ton horizontal furnace and air conditioner system targets a practical market segment: contractors and homeowners needing reliable equipment that fits physical constraints without breaking budgets. This combination unit delivers 120,000 BTU heating output paired with 60,000 BTU cooling capacity in a footprint measuring just 24.5 inches tall, 26 inches wide, and 21.125 inches deep. It's positioned as a direct replacement for several Goodman models, inheriting brand familiarity while offering modern efficiency improvements.
Performance specs show genuine capability. The 96% AFUE furnace efficiency ranks among the best non-condensing options available, translating to measurable savings on natural gas or propane bills. Cooling delivers 13 SEER performance through a single-stage reciprocating compressor and A-coil design, adequate for moderate climates but not optimized for peak summer demand. The variable-speed ECM blower motor runs at maximum 2000 CFM and operates at 77 dB, acceptable for equipment in living areas but noticeable in quiet homes.
Pros & Cons
Pros
- 96% AFUE efficiency exceeds most standard furnaces, reducing heating costs significantly year over year
- 13 SEER cooling performance meets Energy Star thresholds despite 'No' designation, with 60,000 BTU capacity rated for 5-ton systems
- Variable-speed ECM blower motor allows precise airflow control, improving comfort and reducing runtime noise to 77 dB
- Horizontal configuration with 24.5 inch height fits tight attic and crawlspace applications where vertical units won't work
- Two-stage gas burner provides flexible heating output for milder days, reducing unnecessary energy consumption
- PVC/plastic exhaust flue compatibility simplifies venting in modern homes without masonry chimneys
Cons
- Single-stage condenser limits cooling modulation in hot climates, cycling on and off rather than ramping capacity
- SEER 13 is solid but falls behind two-stage competitors at 14-15 SEER for homes prioritizing cooling efficiency
- Reciprocating compressor generates more operational noise and vibration compared to scroll designs, though 77 dB remains acceptable
Who Should Buy
Best For
Contractors installing HVAC systems in homes with space constraints, attics, or crawlspaces where horizontal orientation is mandatory. Homeowners in moderate climates seeking efficient heating with competent cooling who qualify for rebates and prefer lower equipment costs.
Consider Alternatives If
Anyone in hot climates where cooling dominates runtime, or homeowners unwilling to register online for the 10-year warranty, should explore higher-SEER alternatives.
Installation
Installation suits 208/230V single-phase electrical supply with 32.8 to 45 amp breaker sizing. The horizontal orientation requires proper mounting brackets and clear airflow paths, typical for attic installations. PVC exhaust venting simplifies setup compared to traditional metal flue work. Suction line insulation thickness of 3/8 inch comes standard, and refrigerant line connections use 3/8 inch and 7/8 inch sweat fittings requiring competent brazing skills.
Warranty & Reliability
The 10-year parts warranty requires online registration to activate, a common protection gate among mid-tier manufacturers. Coverage is straightforward with no split-term limits, though many HVAC contractors recommend extended service plans for compressor and heat exchanger protection beyond base coverage.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 120,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 77 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368842 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Horizontal |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 24.5" |
| Width | 26" |
| Depth | 21.125" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Replaces | GSX130603, GSX130604, GSX130605, GSX130611, GSX130613, GSX130614 |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.