Review
The Goodman 5-ton upflow system represents a pragmatic choice for homeowners seeking straightforward heating and cooling without premium pricing. This unit pairs a 120,000 BTU, 96% AFUE furnace with a 60,000 BTU, 13 SEER air conditioner in a compact A-coil configuration sized for typical residential installations. It replaces six older Goodman models and carries Energy Star certification, signaling compliance with current efficiency standards.
Heating performance stands out here. The 96% AFUE rating and two-stage burner deliver measurable savings versus older 80-90% units, potentially reducing winter bills by $250-400 annually depending on climate. Cooling efficiency at 13 SEER performs adequately for moderate climates but trails newer competitor models rated 14-16 SEER. The variable-speed ECM blower motor provides soft-start operation and reduces parasitic electric consumption, while single-stage reciprocating compressor keeps costs down at the expense of progressive cooling capacity.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs substantially compared to 80-90% units, translating to $200-400 annual savings in cold climates
- Two-stage burner and variable-speed ECM blower motor enable precise temperature control and lower runtime noise at 77 dBA
- Upflow A-coil configuration fits standard vertical installations with minimal ductwork modification
- Energy Star certified with R454B refrigerant meets current EPA environmental standards
- Lifetime heat exchanger warranty plus 10 years parts coverage with online registration provides solid long-term protection
Cons
- 13 SEER cooling lags behind 14-16 SEER competitors, meaning higher summer energy bills in hot climates
- Single-stage compressor lacks variable capacity for gradual cooling ramp, causing more on-off cycling
- Requires 32.8 to 45-amp breaker sizing, which may necessitate electrical panel upgrades in older homes
Who Should Buy
Best For
Contractors installing replacement systems in established residential markets and homeowners in regions with moderate heating demands who prioritize furnace efficiency over air conditioning performance. This unit works best for those replacing aging 80-85% AFUE furnaces where heating costs dominate annual utility bills.
Consider Alternatives If
Buyers in hot-humid climates like Florida or Arizona should pursue 15-16 SEER units instead, and homes under 1,500 square feet may experience short-cycle inefficiency with this 5-ton capacity.
Installation
Installation follows standard upflow protocol for homes with basements or crawlspaces. The unit requires sweat-type connections using 3/8-inch liquid and 7/8-inch suction lines, with 3/8-inch suction line insulation for efficiency. Plastic or PVC exhaust flue venting is compatible. Electrical demands range from 32.8 to 45 amps, potentially requiring breaker upgrades in homes with older service panels.
Warranty & Reliability
Coverage includes a lifetime heat exchanger warranty and 10 years of parts coverage when you register online. This two-tier structure protects against furnace failure (most expensive component) while providing decade-long parts support for compressor, fan motor, and controls. Registration is required to activate extended coverage.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 120,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 77 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130603, GSX130604, GSX130605, GSX130611, GSX130613, GSX130614 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 24.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7368842 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.