Review
This Goodman/ACiQ 5-ton split system pairs a 120,000 BTU furnace with a 60,000 BTU air conditioner to serve mid-to-large homes across diverse climates. The furnace delivers 96% AFUE efficiency, placing it firmly in the high-efficiency tier, while the AC condenser achieves 13 SEER1 and Energy Star certification. The SKU ACIQ-60-EHPD-UPG replaces six older Goodman models, signaling Goodman's commitment to backward compatibility. Upflow configuration fits attics or basement installs, and the A-coil design simplifies integration with existing ductwork.
Performance numbers tell a practical story. The furnace runs two-stage burners that ramp up gradually, cutting fuel waste and cycling noise. The 2000 CFM variable-speed ECM blower adjusts runtime versus airflow, a smart efficiency feature absent from fixed-speed competitors. Electrical requirements are modest, needing just 32.8 to 45 amps at 115V single-phase 60 Hz. At 77 dB, the condenser operates quietly during cooling. R454B refrigerant carries a lower global warming potential than older blends, reducing environmental impact.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces natural gas bills by 10-15% compared to 80% units
- Two-stage burner modulation minimizes short-cycling and improves comfort consistency
- Variable-speed ECM blower adapts airflow from 0-2000 CFM, lowering electricity use
- Energy Star certified with R454B low-GWP refrigerant
- Lifetime heat exchanger warranty covers the costliest furnace component
Cons
- 13 SEER1 is mid-range; newer systems reach 14-16 SEER2 for greater cooling efficiency
- Single-stage AC condenser cannot modulate capacity, running full power or off
- Plastic/PVC exhaust flue requirement adds installation cost in some retrofit scenarios
Who Should Buy
Best For
Homeowners replacing older 80-90% AFUE systems who want genuine efficiency gains at reasonable cost, and contractors needing a dependable workhorse that balances performance with market competitiveness. This unit excels in moderate climates where heating and cooling loads are balanced.
Consider Alternatives If
Buyers in extreme climates or those demanding cutting-edge cooling efficiency should explore dual-stage or variable-capacity AC units rated 15+ SEER2, which command higher prices but deliver better modulation.
Installation
Installation demands standard HVAC knowledge and tools. The condenser weighs 120 pounds, manageable by two technicians. Liquid and suction lines use 3/8 inch and 7/8 inch sweat fittings respectively, with 3/8 inch insulation thickness required on suction lines. Plastic or PVC exhaust flue is mandatory, which may necessitate venting upgrades in older homes. AHRI Certificate 7368842 confirms matched system performance, mandatory for warranty claims.
Warranty & Reliability
Coverage includes a lifetime heat exchanger warranty and 10 years parts with online registration. The heat exchanger coverage protects your largest expense if cracks develop. The 10-year parts warranty applies to compressor, blower motor, and other components, though labor costs fall on you. Registration is required within 30 days of installation to activate full benefits.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 120,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 77 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130603, GSX130604, GSX130605, GSX130611, GSX130613, GSX130614 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 24.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7368842 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions