Review
The ACiQ 5-ton system with Goodman components bridges the gap between budget-conscious buyers and efficiency enthusiasts. Rated at 97% AFUE for heating and 13 SEER for cooling, this upflow furnace and condenser pairing delivers measurable performance without top-tier pricing. It carries AHRI certification 7424267 and replaces six older Goodman models, making it a solid retrofit option for contractors managing fleet standardization.
The furnace generates 100,000 BTU input with modulating burner control, automatically varying flame intensity rather than cycling on and off. The condenser provides 60,000 BTU cooling output using modern R454B refrigerant. The variable-speed ECM blower reaches 2,000 CFM maximum, feeding heated or cooled air throughout the home while consuming less electricity than fixed-speed motors. This combination achieves its efficiency rating through intelligent modulation across heating and cooling modes.
Pros & Cons
Pros
- 97% AFUE furnace efficiency ranks among the highest available, reducing heating costs significantly in northern climates
- Modulating burner stages adjust output automatically, preventing the on-off cycling that wastes energy in fixed-stage units
- Variable-speed ECM blower motor optimizes airflow and reduces runtime, lowering electricity consumption throughout the year
- 13 SEER cooling with R454B refrigerant meets modern environmental standards while delivering solid summer performance
- PVC/plastic exhaust flue compatibility simplifies installation in retrofit applications where traditional metal venting is problematic
- ACiQ brand reliability with 10-year parts warranty and AHRI certification number 7424267 provides contractor confidence
Cons
- 13 SEER cooling is competent but not exceptional, trails 14-16 SEER models by measurable summer efficiency margins
- Single-stage condenser means air conditioning doesn't modulate like the furnace, resulting in more cycling on mild days
- 77 dB noise level is audible in quiet homes, slightly louder than premium competitors with variable-speed compressors
- Not Energy Star certified despite high furnace efficiency, missing rebate qualification in some utility programs
Who Should Buy
Best For
This system fits contractors building or replacing equipment in colder regions where heating dominates the annual load, and homeowners in natural gas service areas looking to cut winter bills without premium pricing. The 97% AFUE pays dividends when furnaces run 6-8 months annually.
Consider Alternatives If
Buyers in hot climates prioritizing cooling efficiency should look at 14+ SEER single-stage or variable-capacity units. Homeowners avoiding registration paperwork will miss the 10-year warranty benefit.
Installation
The upflow configuration suits basement and closet installations with horizontal return air routing. Plastic PVC exhaust flue simplifies venting compared to traditional metal, reducing installation complexity and material cost. Right-side flue placement offers flexibility in mechanical rooms with space constraints. The unit weighs 120 pounds and measures 30 inches tall by 21 inches wide and deep, fitting standard equipment closets without modification.
Warranty & Reliability
ACiQ backs this system with a 10-year parts warranty when registered online within 60 days of installation. The Goodman evaporator coil receives separate coverage. This duration matches industry standards but trails some premium brands offering 12-15 years. Online registration is simple but mandatory to activate coverage, so contractors should document serial numbers at startup.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 100,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 77 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| AHRI Certificate Number | 7424267 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Energy Star | No |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Replaces | GSX130603, GSX130604, GSX130605, GSX130611, GSX130613, GSX130614 |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |