Independent Review · Updated June 2026

5 Ton 13 SEER Goodman Air Conditioner with Vertical 21" Uncased Coil

Budget-friendly 5-ton coil with solid 13 SEER efficiency and straightforward installation

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
5 Ton 13 SEER Goodman Air Conditioner with Vertical 21
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ coil is ideal for contractors replacing mid-range Goodman systems or homeowners upgrading older equipment on a budget. The 13 SEER rating delivers respectable efficiency gains, and the vertical A-coil design works seamlessly with both upflow and downflow configurations.

Review

The ACiQ 5-ton vertical A-coil with 13 SEER represents straightforward, no-frills cooling capacity for residential applications. This unit replaces six legacy Goodman models, GSX130603 through GSX130614, making it a drop-in solution for contractors managing fleet upgrades. At 60,000 BTU cooling capacity, it handles mid-sized homes effectively. The vertical uncased design and dual configuration support (upflow and downflow) make it flexible for retrofit scenarios where ductwork routing varies.

Performance metrics show a 13 SEER1 rating, which meets baseline minimum efficiency standards without entering premium territory. The 60,000 BTU output pairs with single-stage reciprocating compressor technology, delivering consistent cooling without variable-speed complexity. Operating on 208/230V single-phase power, it requires a 32.8 to 45-amp breaker, standard for residential installations. R454B refrigerant choice reflects current EPA compliance, though this does not improve efficiency relative to R410A predecessors.

Pros & Cons

Pros

  • 13 SEER efficiency provides solid baseline performance without premium pricing
  • Vertical 21-inch A-coil fits standard ductwork spaces with 40-inch height and 29-inch width
  • R454B refrigerant aligns with current EPA standards and future-proofs your system
  • 10-year warranty with online registration covers manufacturing defects comprehensively
  • Single-stage reciprocating compressor is proven durable and widely serviced across regions

Cons

  • 13 SEER is entry-level efficiency, not optimal for high-cost utility areas
  • 77 dBA noise level is louder than premium competitors, noticeable in quiet neighborhoods
  • No Energy Star certification limits rebate eligibility in some utility programs

Who Should Buy

Best For

Residential contractors handling replacement jobs on Goodman GSX systems, or homeowners in moderate-climate zones seeking reliable performance without high-efficiency pricing. This works well for systems serving 2,000 to 2,500 square foot homes.

Consider Alternatives If

Anyone in hot, humid climates or high-electricity-cost regions should consider 14+ SEER units, and commercial applications requiring quieter operation should explore alternatives.

5 Ton 13 SEER Goodman Air Conditioner with Vertica
$0
Buy at HVACDirect →

Installation

Installation follows conventional A-coil procedures with sweat-style valve connections. Line sets require 3/8-inch liquid and 1 1/8-inch suction lines, both industry standard. The 1/2-inch suction line insulation thickness meets heat transfer requirements for 50-foot maximum runs. Dimensional footprint of 40 inches tall, 29 inches wide and deep fits most standard equipment closets and attic spaces. Uncased design requires field-supplied cabinetry.

Warranty & Reliability

The 10-year parts warranty activates upon online registration and covers manufacturing defects to compressor, coil, and controls. This is competitive mid-range coverage. Labor and refrigerant are excluded, as typical. Registration is straightforward but required, so buyers must complete it promptly after installation to secure full protection.

Specifications

SKUACIQ-60-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU60,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)77
Weight (in lbs)120.000000
FeatureSpec
ConfigurationUpflow / Downflow
Liquid Line3/8"
Suction Line1 1/8"
Tonnage5 Ton
StyleA-Coil
Height40"
Width29"
Depth29"
ResourcesGoodman Installation Manual Goodman Specifications Goodman Technical Manual Goodman Warranty Information Goodman Brochure Goodman Service Instructions Goodman Kit Instructions Goodman Parts Manual You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ReplacesGSX130603, GSX130604, GSX130605, GSX130611, GSX130613, GSX130614
Energy StarNo
SEER1 (Efficiency)13
Condenser StagesSingle Stage
Compressor TypeReciprocating
Liquid Valve Size3/8"
Max Breaker Size45 amps
Min. Breaker Size32.8 amps
Valve TypeSweat
Suction Line Insulation Thickness1/2"
Length50 feet

Frequently Asked Questions

What tonnage and BTU output does this coil deliver? +
This is a 5-ton unit rated at 60,000 BTU cooling capacity. It suits homes between 2,000 and 2,500 square feet in moderate climates. For hotter regions, oversizing to 5.5 or 6 ton may improve comfort and seasonal efficiency.
Will this coil work with my existing 208V or 230V electrical panel? +
Yes. The unit operates on both 208V and 230V single-phase 60 Hz power. Verify your existing disconnect and breaker accommodate the 32.8 to 45-amp range. Most residential panels support this load without upgrades.
How does 13 SEER compare to newer systems? +
13 SEER is entry-level by today's standards. Premium systems reach 16 to 18 SEER. In regions with $0.15 per kWh electricity, higher SEER units recover cost over 10 to 12 years. In moderate-cost areas, 13 SEER is adequate.
Can I replace my existing Goodman coil with this ACiQ unit? +
Yes, if your current unit is one of the six replaced models (GSX130603-130614). Verify refrigerant compatibility and line size match. R454B systems require newer oil and proper evacuation procedures. Always consult the Goodman installation manual.
What does the 10-year warranty actually cover? +
It covers compressor and coil defects after online registration. Labor, refrigerant, and electrical components are excluded. Damage from improper installation or maintenance voids coverage.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.