Review
The ACiQ 5-ton combination system pairs a gas furnace with an air conditioning condenser in a practical upflow configuration. This unit targets the mainstream market where contractors and homeowners prioritize dependable performance over premium features. Goodman's reputation for straight-forward engineering shows through in the specification sheet, with familiar two-stage burner technology and scroll compressor design that service techs know how to maintain.
On the cooling side, 14 SEER with 57,000 BTU output represents solid mid-tier efficiency for 5-ton applications, using R454B refrigerant with standard 3/8 inch liquid and 1 1/8 inch suction lines. The furnace delivers 58,000 BTU heating at 80% AFUE through dual-stage burners, enabling modest modulation during shoulder seasons. Multi-speed blower reaches 2000 CFM maximum, supporting proper air distribution across the 50-foot suction line insulation package included.
Pros & Cons
Pros
- 14 SEER rating delivers reliable cooling efficiency for mid-tier systems, with 57,000 BTU capacity handling most 5-ton applications
- 80% AFUE furnace provides adequate heating with two-stage burner for better temperature control and comfort
- Multi-speed blower motor and maximum 2000 CFM airflow accommodate both heating and cooling seasons effectively
- A-Coil design with upflow/horizontal configuration fits standard ductwork in most installations
- 10-year warranty with online registration offers reasonable protection at this price point
- R454B refrigerant provides safer environmental profile than older R22 systems
Cons
- 80% AFUE is entry-level for furnace efficiency, meaning higher heating bills compared to 95%+ units in cold climates
- Single-stage condenser can't modulate cooling capacity, so it runs full-blast or not at all, reducing efficiency on mild days
- 77 dB noise level runs louder than some competitors, potentially noticeable in quiet residential settings
- Not Energy Star certified, limiting tax credits or rebate eligibility in some states
Who Should Buy
Best For
Homeowners in transitional climates (ASHRAE zones 4-6) replacing systems that are 10+ years old and seeking straightforward reliability over cutting-edge efficiency. Budget-conscious buyers wanting proven Goodman/ACiQ quality without paying for premium variable-capacity features will appreciate this unit.
Consider Alternatives If
Buyers in very cold climates (zones 1-3) should look for 95%+ AFUE furnaces instead, and anyone in hot climates needing maximum cooling efficiency should consider variable-speed condensers with higher SEER ratings.
Installation
The upflow A-Coil design installs in most standard closets or utility spaces with 38.25 inch height, 35.5 inch width and depth fitting conventional 2x4 framing. Requires 208/230V single-phase 60Hz electrical service with 34.6 to 60 amp breaker, and metal exhaust flue for gas furnace safety. Installation typically takes qualified techs 4-6 hours including ductwork connections and refrigerant charging.
Warranty & Reliability
ACiQ backs this system with 10 years parts coverage upon online registration, providing solid middle-ground protection without lifetime coverage. Registration process is straightforward on Goodman's site, and the warranty covers compressor failure, heat exchanger cracks, and most major components excluding wear items like capacitors.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 57,000 |
| Heating BTU | 58,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 77 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Tonnage | 5 Ton |
| Style | A-Coil |
| Height | 38.25" |
| Width | 35.5" |
| Depth | 35.5" |
| Resources | Goodman Specifications Goodman Customer Brochure Goodman Installation Instructions Goodman Kit Instructions Goodman Parts Manual Goodman Service Manual Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Multi-Speed |
| Maximum CFM | 2000 |
| Burner Stages | Two |
| Fuel Type | Gas |
| Replaces | GSZ140611 |
| Energy Star | No |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 60 amps |
| Min. Breaker Size | 34.6 amps |
| Valve Type | Sweat |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.