Independent Review · Updated June 2026

Goodman 5 Ton 14 SEER 80% 80,000 BTU Furnace & AC System - R410A Upflow

Solid mid-range 5-ton system balancing 14 SEER efficiency with practical 80% AFUE heating

7.8
IndustrialRank Score
Efficiency
8.0
Reliability
7.9
Value
7.6
Installation
8.2
Warranty
8.0
Goodman 5 Ton 14 SEER 80% 80,000 BTU Furnace & AC System - R410A Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ packaged unit works best for budget-conscious homeowners in moderate climates who want proven cooling efficiency without premium pricing. It's a no-frills workhorse that prioritizes straightforward installation and reasonable long-term durability over cutting-edge features.

Review

The ACiQ 5-ton packaged heat pump and furnace combination represents the practical middle ground in residential HVAC equipment. Positioned below premium brands like Carrier and Lennox but above bottom-tier units, this system targets contractors and homeowners seeking reliable cooling and heating without premium pricing. The R454B refrigerant formulation reflects current environmental standards, though supply chain and technician familiarity varies by region.

Cooling performance delivers 57,000 BTU at 14 SEER efficiency, meeting modern baseline standards. Heating provides 58,000 BTU at 80% AFUE using a single-stage burner, adequate for moderate climates but not optimal for extreme cold regions. The multi-speed PSC blower maxes at 2,000 CFM, supporting 30-inch height in upflow or downflow configurations. At 77 dB, noise levels run noticeably higher than inverter-driven competitors, something apartment-adjacent installations should consider.

Pros & Cons

Pros

  • 14 SEER cooling efficiency meets current standards and qualifies for some utility rebates in most regions
  • 5-ton capacity handles typical single-family homes up to 2,500 square feet effectively
  • 80% AFUE gas furnace provides acceptable heating performance for most climates
  • Single-stage compressor and burner design means fewer components to fail long-term
  • Multi-speed PSC blower motor at 2,000 CFM max airflow supports flexible ductwork configurations
  • 10-year warranty with online registration covers major components adequately

Cons

  • Cooling output of 57,000 BTU and heating output of 58,000 BTU are slightly undersized compared to stated 5-ton rating, requiring careful load calculation
  • R454B refrigerant is newer with fewer qualified technicians available in some service areas
  • 77 dB noise level runs louder than high-efficiency competitors, noticeable during operation
  • Single-stage operation means the system runs full capacity or off, reducing part-load efficiency in mild weather
  • No Energy Star certification indicates it misses higher efficiency thresholds available at similar price points
  • Spec sheet discrepancy: product name says R410A but specs list R454B refrigerant

Who Should Buy

Best For

Budget-conscious homeowners replacing 15+ year old systems who value installation simplicity and want mid-tier efficiency without premium costs. Contractors installing in price-sensitive markets will appreciate straightforward serviceability and standard refrigerant connections.

Consider Alternatives If

Skip this if you need cutting-edge efficiency ratings (16 SEER+), live in extremely hot climates requiring oversized cooling capacity, or want variable-stage compressors that modulate output for quieter, more efficient part-load operation.

Goodman 5 Ton 14 SEER 80% 80,000 BTU Furnace & AC
$0
Buy at HVACDirect →

Installation

Installation requires standard 208/230V single-phase 60Hz service with 34.6-60 amp breaker sizing flexibility. The compact 21-inch width and 30-inch height fit most mechanical closets. Metal flue venting required at top exit point. Sweat-type valve connections use standard 3/8-inch and 7/8-inch lines with 50-foot maximum suction line length and 1/2-inch insulation thickness. Setup is straightforward for experienced technicians.

Warranty & Reliability

Ten-year parts warranty on compressor, heat exchanger, and covered components requires online registration to activate. Coverage is comprehensive for major failures but excludes wear items like capacitors and contactors. Registration is simple but mandatory, so don't skip it at installation. This warranty period is competitive for equipment at this price tier.

Specifications

SKUACIQ-60-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU57,000
Heating BTU58,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)77
Weight (in lbs)120.000000
FeatureSpec
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementMetal
Furnace Efficiency / AFUE80%
Blower MotorMulti Speed - PSC
Maximum CFM2000
ConfigurationUpflow / Downflow
Flue LocationTop
Burner StagesSingle
Fuel TypeGas
Height30"
Width21"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
ReplacesGSZ140611
Energy StarNo
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Max Breaker Size60 amps
Min. Breaker Size34.6 amps
Tonnage5 Ton
Valve TypeSweat
Liquid Line3/8"
Suction Line1 1/8"
StyleA-Coil
Suction Line Insulation Thickness1/2"
Length50 feet

Frequently Asked Questions

Why does the product name mention R410A but specs show R454B? +
This appears to be a specification sheet error or product line transition. Verify with the supplier before purchase. R454B is the actual refrigerant, which is current EPA-compliant but may have limited technician availability in some areas. Always confirm with your local installer.
Will this system fit my existing ductwork and electrical service? +
The compact 21x21x30-inch footprint fits most installations. Electrical requires 208/230V single-phase at 34.6-60 amps depending on configuration. Ductwork compatibility depends on your existing system's capacity. Have a technician verify your CFM requirements match the 2,000 CFM maximum before committing.
How does 14 SEER compare to other systems I'm considering? +
14 SEER is solid mid-range efficiency, common for systems in the 5,000-8,000 dollar range. Premium brands hit 16-18 SEER but cost significantly more. Modern baseline is 13-14 SEER, so this performs adequately without premium investment for most homeowners.
Is the 58,000 BTU heating output enough for my 2,400 square foot home? +
Rule of thumb is 40-50 BTU per square foot in moderate climates. Your home needs roughly 96,000-120,000 BTU total, so supplemental heating or this as a secondary system may be necessary. Have a load calculation done before purchase to avoid undersizing.
What does the 10-year warranty actually cover? +
Compressor, heat exchanger, condenser coil, and refrigerant leaks are covered. Labor is typically not included, and online registration is required. Exclusions cover capacitors, contactors, and wear items. Review the actual warranty document before installation.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.