Review
The Goodman 5-ton upflow system represents a straightforward approach to residential heating and cooling. It pairs a 100,000 BTU gas furnace with a matching air conditioner in a compact A-coil configuration, designed for homes averaging 2,000 to 2,400 square feet. Online Supply positions this unit as a value option for contractors and homeowners balancing performance with budget constraints. The upflow orientation suits basement or utility closet placement in most new construction and retrofit scenarios.
Performance numbers reveal a competent mid-range system. The furnace delivers 92% AFUE efficiency, meaning 92 cents of every heating dollar converts to usable warmth, a respectable figure for single-stage combustion. Cooling capacity reaches 60,000 BTU with 14 SEER efficiency, translating to roughly 14 BTU of cooling per watt consumed. The multi-speed blower motor supports airflow up to 1,600 CFM, enabling proper air distribution across ductwork. These specs won't rival premium systems, but they align well with homes seeking cost-effective climate control.
Pros & Cons
Pros
- 92% AFUE furnace hits high heating efficiency for gas-fired systems, reducing winter fuel bills noticeably
- 14 SEER cooling efficiency meets modern standards for decent summer performance across climate zones
- 5-ton capacity handles most single-family homes up to 2,500 square feet without oversizing issues
- Multi-speed blower motor allows flexible airflow matching, improving comfort and reducing noise
- Single-stage scroll compressor design is durable and field-serviceable by most HVAC contractors
- 10-year warranty with online registration provides meaningful protection on both components
Cons
- Single-stage compressor and burner mean less modulation, so efficiency gains diminish in mild weather
- 75 dBA noise level is moderate but noticeable, especially during heating cycle startup
- Not Energy Star certified, so it misses rebate eligibility in some utility programs
- R410A refrigerant requires proper recovery and handling, adding to service costs over time
Who Should Buy
Best For
Homeowners with homes between 1,800 and 2,500 square feet who want reliable performance without premium features or pricing. Contractors looking to balance efficiency ratings against customer budgets will find this system a practical middle-ground choice.
Consider Alternatives If
Anyone seeking Energy Star certification or variable-capacity equipment should look at higher-tier Goodman models or competitors like Lennox or Carrier.
Installation
Installation requires standard HVAC practices and materials. The unit needs a 32.8 to 50-amp electrical circuit at 115V, manageable on most residential panels. Refrigerant line sizing calls for 3/8-inch liquid and 7/8-inch suction lines with 3/8-inch insulation on the suction side. Gas hookup is straightforward single-stage burner work. PVC flue venting exits the right side, simplifying routing in attics or crawlspaces. Professional installation typically takes 4 to 6 hours.
Warranty & Reliability
Goodman covers this system for 10 years when registered online, a standard duration in the industry. Coverage includes compressor and furnace components, protecting against manufacturing defects. Registration is simple and typically completed at installation. Extended warranties are available from Online Supply if additional peace of mind matters to your buying decision.
Specifications
| SKU | LS38783830 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 60,000 |
| Heating BTU | 100,000 |
| Refrigerant | R410A |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 30.000000 |
| Feature | Spec |
| Energy Star | No |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 50 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Height | 34.5" |
| Width | 21" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 92% |
| Blower Motor | Multi Speed |
| Maximum CFM | 1600 |
| Flue Location | Right |
| Burner Stages | Single |
| Fuel Type | Gas |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions