Independent Review · Updated June 2026

5 Ton 14 SEER 92% AFUE 80,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow

Solid 14 SEER heat pump with 92% AFUE furnace backup for mixed climates

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
5 Ton 14 SEER 92% AFUE 80,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ system works best for contractors and homeowners in moderate climates who want a dependable hybrid heating solution without premium pricing. The 92% AFUE gas furnace and 14 SEER heat pump combination handles shoulder seasons efficiently while providing reliable backup heat during cold snaps.

Review

The ACiQ 5-ton upflow system represents a practical middle-market solution for contractors balancing cost with performance. This hybrid approach combines a 92% AFUE gas furnace with a 14 SEER heat pump condenser in one package, eliminating complicated dual-unit coordination. Goodman's ACiQ line has gained contractor trust over the past decade as a no-nonsense alternative to premium brands, and this unit maintains that reputation with straightforward single-stage compressor design and proven scroll technology.

Performance specs hold up well for the price point. The furnace delivers 58,000 BTU heating output with 92% AFUE efficiency, meaning 92 cents of every fuel dollar converts to usable heat. The heat pump side produces 57,000 BTU cooling at 14 SEER, adequate for 5-ton applications in mixed climates. The multi-speed blower supports maximum 1600 CFM, ensuring even distribution across ductwork. Operating on 208/230V single-phase power with a 60-amp breaker requirement, electrical integration is straightforward for most residential installations.

Pros & Cons

Pros

  • 92% AFUE furnace efficiency with single-stage burner for predictable fuel consumption
  • 14 SEER cooling efficiency at 5 tons, delivering 57,000 BTU output
  • Multi-speed blower motor optimizes airflow between heating and cooling cycles
  • R454B refrigerant aligns with current EPA regulations and future compliance
  • 10-year warranty with online registration covers most failure scenarios

Cons

  • Single-stage condenser limits part-load efficiency during mild weather cycling
  • 77 dB noise level runs louder than some competitors, noticeable during operation
  • No Energy Star certification despite respectable SEER and AFUE ratings

Who Should Buy

Best For

Contractors installing budget-conscious systems in ASHRAE zones 4-7 where heating and cooling loads are roughly balanced will appreciate this unit's straightforward engineering and proven ACiQ reliability. Homeowners replacing aging gas furnaces with heat pump systems should consider this as a practical middle ground between cost and efficiency.

Consider Alternatives If

Buyers in very cold climates needing primarily heating capacity should look at dedicated furnaces, and those seeking ultra-quiet operation or maximum efficiency ratings should explore variable-capacity alternatives.

5 Ton 14 SEER 92% AFUE 80,000 BTU Goodman Gas Furn
$0
Buy at HVACDirect →

Installation

This upflow configuration fits standard basement or utility closet spaces with its 30 inches tall, 21 inches wide and deep footprint. The plastic/PVC exhaust flue requirement simplifies venting compared to metal ductwork, reducing installation labor. Refrigerant lines require 3/8-inch liquid and 1 1/8-inch suction connections with 1/2-inch insulation, using sweat valve connections. Contractors should plan for 50 feet of pre-insulated lineset, which ACiQ provides ready-to-use.

Warranty & Reliability

The 10-year warranty requires online registration to activate full coverage. This period covers compressor failure, refrigerant leaks, and component defects under normal operation. Registration takes minutes through Goodman's website. Parts availability through HVAC wholesalers remains strong due to Goodman's national network, meaning warranty claims rarely exceed 48 hours for replacement components in most service areas.

Specifications

SKUACIQ-60-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU57,000
Heating BTU58,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)77
Weight (in lbs)120.000000
FeatureSpec
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE92%
Blower MotorMulti Speed
Maximum CFM1600
ConfigurationUpflow / Downflow
Flue LocationRight
Burner StagesSingle
Fuel TypeGas
Height30"
Width21"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
ReplacesGSZ140611
Energy StarNo
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Max Breaker Size60 amps
Min. Breaker Size34.6 amps
Tonnage5 Ton
Valve TypeSweat
Liquid Line3/8"
Suction Line1 1/8"
StyleA-Coil
Suction Line Insulation Thickness1/2"
Length50 feet

Frequently Asked Questions

How does 14 SEER compare to modern standards? +
14 SEER meets mid-tier efficiency expectations but falls below current premium offerings reaching 16-18 SEER. For moderate climates with 500-800 cooling hours annually, the energy savings versus 10 SEER systems justify the upgrade cost within 6-8 years through lower electric bills.
Will this unit work with existing ductwork from my old furnace? +
Most likely yes, if your current system is 5 tons and upflow configuration. The 1600 CFM maximum blower works with standard residential ductwork designed for that tonnage. Have an HVAC contractor evaluate static pressure and duct sizing before installation to ensure proper performance.
Does it automatically switch between heat pump and furnace? +
Yes, a standard thermostat controls the switching logic. In heating mode below roughly 35 degrees outdoor temperature, the system defaults to furnace operation for better efficiency. The heat pump handles milder days and cooling season work automatically based on your setpoint.
Why no Energy Star label if SEER is 14 and AFUE is 92 percent? +
Energy Star certification requires meeting both efficiency thresholds AND additional seasonal performance metrics. This unit hits the numbers but may fall short on combined seasonal heating and cooling averages that Energy Star applies. Performance remains solid without the label.
What does the 10-year warranty actually cover? +
With registration, you get compressor, refrigerant charge, and sealed components. Blower motors, ignition systems, and control boards typically run 5 years. Review the specific coverage document before purchase to understand exclusions.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.