Review
The ACiQ 5-ton combo system combines a Goodman furnace and air conditioner in a single downflow unit rated for 100,000 BTU heating and 60,000 BTU cooling. Positioned in the mid-efficiency segment, this system targets contractors and homeowners who want reliable performance without premium costs. The downflow configuration makes it suitable for installations where horizontal or downward air discharge simplifies ductwork design. ACiQ maintains solid market reputation for straightforward, no-nonsense HVAC equipment that emphasizes function over flashy features.
Heating efficiency hits 96% AFUE, a respectable figure that beats standard 80-90% equipment by 6 to 16 percentage points on seasonal performance. The cooling side delivers 14 SEER1 at 60,000 BTU, meeting Energy Star qualification for air-side efficiency. A variable-speed ECM blower motor manages 2,000 CFM maximum and keeps sound output at 75 dB, quieter than many single-stage compressor units. Two-stage burner operation enables the furnace to run at reduced capacity during mild weather, lowering on-off cycling and improving comfort consistency.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs significantly compared to 80-90% baseline units
- 14 SEER cooling at 60,000 BTU meets modern efficiency standards without extreme expense
- Variable-speed ECM blower motor optimizes airflow and reduces runtime noise to 75 dB
- Two-stage burner allows modulation for more consistent comfort and lower energy waste
- PVC/plastic exhaust flue compatibility simplifies installation in tight spaces or retrofit applications
- 10-year warranty with online registration provides solid protection for critical components
Cons
- Single-stage air conditioner lacks capacity modulation for premium comfort in variable conditions
- No SEER2 rating provided, only SEER1 at 14, limiting direct comparison to newer equipment standards
- Requires 32.8 to 50-amp electrical service, which may necessitate panel upgrades in older homes
Who Should Buy
Best For
Contractors and homeowners in moderate climates seeking a balanced heating and cooling solution without stratospheric costs. This system works particularly well for downflow installations where space is limited or existing ductwork demands specific configurations.
Consider Alternatives If
Buyers in extreme climates requiring variable-capacity cooling or those seeking the absolute latest efficiency tier should evaluate single-stage limitations and consider dual-stage alternatives.
Installation
This downflow unit requires standard 115V, 1-phase, 60 Hz electrical service with breaker sizing between 32.8 and 50 amps. PVC/plastic exhaust flue compatibility simplifies venting in tight spaces where metal ducting proves impractical. Line sets use standard 3/8-inch liquid and 7/8-inch suction connections. Weight of 120 pounds and dimensions of 30 inches high by 21 inches wide by 21 inches deep fit most utility closets or basement installations without special reinforcement.
Warranty & Reliability
ACiQ backs this unit with a 10-year warranty on compressor and components when you register online after purchase. This term is competitive for mid-tier equipment and provides meaningful protection against early failure. Registration is quick and typically required within 30 days of installation. Coverage excludes normal wear and does not extend to refrigerant in most cases, so verify terms with your contractor.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 100,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 50 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368844 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |