Review
The ACiQ 5-ton combo system pairs a Goodman furnace with an air conditioning unit in a downflow configuration rated for 100,000 BTU heating and 60,000 BTU cooling. This mid-market offering targets contractors and homeowners seeking balanced performance without premium pricing. The unit earns AHRI certification (7368844), indicating proper engineering and tested compatibility between components. At 120 pounds and compact dimensions of 21 by 21 by 30 inches, it fits standard equipment closets and basement installations with reasonable logistics.
Performance centers on the 96% AFUE furnace efficiency and 14 SEER cooling rating, both solid for 2024 equipment. The two-stage burner modulates output based on demand, reducing short-cycling and improving comfort control. The variable-speed ECM blower motor operates at up to 2000 CFM and adjusts speeds to match heating and cooling cycles, cutting unnecessary runtime. R454B refrigerant reflects current EPA direction away from older compounds. These specs deliver measurable cost reductions for homeowners upgrading from 1990s-era systems with 80% furnace efficiency and 10-11 SEER cooling.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs significantly versus 90-92% units
- 14 SEER cooling with R454B refrigerant meets current environmental standards
- Variable-speed ECM blower motor optimizes airflow and reduces energy waste
- Two-stage burner allows modulated heating for better comfort and efficiency
- PVC exhaust compatibility simplifies installation in many retrofit scenarios
Cons
- 14 SEER is good but not exceptional compared to 16+ SEER premium systems
- Single-stage condenser limits cooling modulation during partial-load conditions
- No Energy Star certification despite high efficiency ratings
- 75 dBA noise level may be noticeable in quiet spaces during operation
Who Should Buy
Best For
Homeowners replacing older 80-90% AFUE furnaces in areas with balanced heating and cooling needs will see meaningful utility savings. Contractors installing downflow systems in basements or attics appreciate the straightforward PVC exhaust and standard 208/230V single-phase electrical requirements.
Consider Alternatives If
Buyers seeking ultra-high efficiency (16+ SEER) or seeking Energy Star certification should explore competing brands, as this unit targets the mainstream efficiency market rather than premium tier.
Installation
Downflow orientation requires adequate space below equipment for ductwork drop, common in basement or attic installations. Electrical connection needs 208 or 230V single-phase 60 Hz service with 32.8 to 50 amp breaker capacity, standard in most residential panels. PVC exhaust flue simplifies venting compared to metal pipe in cold climates. Variable-speed blower requires compatible thermostat capable of communicating with ECM motor, adding minor cost if upgrading older controls.
Warranty & Reliability
ACiQ provides 10 years parts and labor coverage upon online registration, a meaningful commitment for system longevity. Goodman's evaporator coil receives separate warranty protection listed in documentation. Registration requirement is straightforward but mandatory to activate coverage, so buyers must complete this step promptly after installation to secure full protection.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 100,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| AHRI Certificate Number | 7368844 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 50 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions