The ACiQ 5-ton gas furnace and air conditioner system represents a pragmatic choice for residential HVAC replacement in standard and challenging installation spaces. Manufactured by a supplier trusted by contractors nationwide, this unit combines a 120,000 BTU heating capacity with 60,000 BTU cooling in a single horizontal package. The A-coil configuration makes it ideally suited for attics, crawlspaces, and tight basements where vertical equipment won't fit. It runs on natural gas or propane, accepts standard PVC venting, and carries Goodman's established reputation for dependable performance across thousands of installations.
Performance numbers matter, and this system delivers credible efficiency across both heating and cooling modes. The 96% AFUE rating means nearly all fuel converts to usable heat, translating to lower winter utility bills compared to 90-93% baseline models. On the cooling side, 14 SEER1 efficiency provides solid seasonal performance, though single-stage condenser operation means the compressor runs at full 5-ton capacity or shuts off with no intermediate modulation. The variable-speed ECM blower motor adjusts between 0 and 2000 CFM, allowing the system to match demand and reduce unnecessary runtime. Two-stage burner heating further optimizes part-load efficiency during milder weather.
Pros & Cons
Pros
- 96% AFUE heating efficiency minimizes natural gas or propane waste and lowers monthly utility bills significantly
- 14 SEER1 cooling rating balances efficiency with cost, outperforming minimum 13 SEER requirements in most regions
- Variable-speed ECM blower motor adjusts output between 0 and 2000 CFM for precise comfort control and reduced noise
- Two-stage burner delivers modulating heat output, reducing energy consumption during mild weather
- Horizontal A-coil configuration fits tight attic or basement installations where vertical models won't work
- PVC/plastic exhaust compatibility simplifies venting in retrofit applications
- 10-year parts warranty with online registration covers manufacturing defects and compressor failure
Cons
- 75 dB operating noise level ranks on the louder side for furnace/AC combos, noticeable during compressor cycles
- Single-stage condenser limits cooling modulation, meaning the compressor runs full capacity or off with no middle ground
- No Energy Star certification signals this isn't cutting-edge efficiency, though 96% AFUE and 14 SEER are solid performers
- R454B refrigerant handling requires certified technicians, limiting repair options to shops with proper EPA training
Who Should Buy
Best For
Contractors installing replacement systems in homes with attic or horizontal mounting constraints will appreciate the compact 24.5-inch height and proven Goodman/ACiQ reliability. Homeowners in moderate climates seeking honest efficiency without premium costs should consider this system's reasonable balance of performance and price.
Consider Alternatives If
Buyers demanding ultra-quiet operation or maximum cooling modulation should explore variable-capacity condenser models, which typically run 3-5 dB quieter and adjust capacity in stages.
Installation
This horizontal configuration requires standard 3/8-inch liquid and 7/8-inch suction line connections with 3/8-inch insulation on the suction line. Electrical demands fall between 32.8 and 50 amps at 208/230V single phase, so most homes require a dedicated 40-50 amp breaker. PVC exhaust simplifies venting through exterior walls or roofs. Technicians need EPA certification for R454B refrigerant handling. Installation complexity remains moderate for experienced HVAC contractors familiar with horizontal equipment layouts.
Warranty & Reliability
ACiQ backs this system with a 10-year parts warranty upon online registration, covering compressor, blower motor, and heat exchanger defects. This timeframe matches industry standard for mid-tier equipment and protects against manufacturing failures, though it excludes wear items like capacitors and contactors. Warranty claims require proof of professional installation, so hire a certified technician to ensure coverage eligibility.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 120,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| AHRI Certificate Number | 7368842 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Horizontal |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 24.5" |
| Width | 26" |
| Depth | 21.125" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 50 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |