Review
The ACiQ 5-ton gas furnace and air conditioner system positions itself squarely in the bread-and-butter market segment, targeting homeowners and contractors who refuse to overpay for unnecessary features. Rebranded Goodman equipment carries decades of field reliability and an established service network across North America. At this price point, you're trading some premium features and efficiency gains for transparent, straightforward performance specs that installers know how to service.
Heating delivers 120,000 BTU at 96% AFUE efficiency, converting nearly all fuel to usable warmth and cutting heating bills compared to 80-90% models. Cooling produces 60,000 BTU at 14 SEER, well ahead of the 13 SEER federal baseline. The two-stage burner and ECM blower motor work together to modulate output smoothly, avoiding overshooting setpoints. Sound output measures 75 dB during operation, acceptable for basement or garage mounting but noticeable near living spaces.
Pros & Cons
Pros
- 96% AFUE furnace efficiency ranks in the top tier for gas heating, reducing winter fuel costs substantially
- 14 SEER cooling efficiency exceeds federal minimums by a significant margin without jumping to premium pricing
- Two-stage burner and single-stage compressor provide precise temperature control and steady operation
- ECM multi-speed blower motor adjusts airflow dynamically, improving comfort and reducing short cycling
- PVC flue compatibility simplifies venting in retrofit applications where metal flues create space conflicts
- 10-year warranty with online registration covers parts, providing solid protection against manufacturer defects
Cons
- Not ENERGY STAR certified, which may disappoint buyers chasing maximum efficiency rebates or green credentials
- 75 dB noise level runs slightly louder than premium models, noticeable during compressor operation
- R454B refrigerant requires technicians trained on newer blend compatibility and leak detection protocols
Who Should Buy
Best For
This system works best for homeowners in mixed climates upgrading 10-15 year old equipment who want proven reliability without premium pricing. It's also ideal for contractors managing multiple residential projects where standardized, serviceable components keep inventory lean.
Consider Alternatives If
Skip this if you prioritize ENERGY STAR certification, need the absolute quietest operation, or live in extreme heating climates where 120,000 BTU capacity may prove undersized for whole-home comfort.
Installation
Installation requires 208-230V single-phase 60Hz power with a 32.8 to 50-amp breaker. The unit accepts both upflow and downflow configurations, fitting most existing ductwork layouts. PVC flue requirements eliminate expensive metal vent modifications in tight spaces. Height and width (38.25 inches and 35.5 inches) fit standard basement utility closets. A licensed technician should handle refrigerant charge and electrical connections.
Warranty & Reliability
Goodman covers parts and labor for 10 years when you register online after installation. This protection shields against compressor failure, heat exchanger cracks, and blower motor defects. Coverage begins from installation date, not purchase date, so timing documentation during commissioning matters. No extended warranty options are listed, so 10 years represents your ceiling.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 120,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Multi-Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Gas |
| Height | 38.25" |
| Width | 35.5" |
| Depth | 35.5" |
| Resources | Goodman Installation Manual Goodman Specifications Goodman Brochure Goodman Warranty Information Goodman Service Instructions Goodman Kit Instructions Goodman Parts Manual You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Tonnage | 5 Ton |
| Style | A-Coil |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 50 amps |
| Min. Breaker Size | 32.8 amps |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |