Review
The ACiQ 5-ton downflow system represents a practical middle ground for HVAC professionals navigating tight installation spaces. Goodman's respected manufacturing platform, wrapped in an aggressive price point, makes this unit attractive for both residential retrofits and new construction. The downflow configuration and horizontal capability address a real market gap where standard upflow equipment simply won't fit, whether that's a basement installation or cramped attic scenario.
Performance specs tell a clear story of heating-focused design. The 97% AFUE rating with a modulating burner delivers exceptional gas furnace efficiency, consuming significantly less fuel than 80-85% AFUE competitors. Cooling delivers 60,000 BTU at 14 SEER1 via a scroll compressor and R454B refrigerant, respectable but not aggressive compared to newer two-stage units hitting 16+ SEER. The variable-speed ECM blower, rated to 2,000 CFM maximum, adjusts output dynamically and reduces the noise penalty typical of single-speed motors.
Pros & Cons
Pros
- Modulating burner reduces heating cycles and energy waste compared to single-stage units
- 97% AFUE heating efficiency delivers near-maximum performance, reducing gas consumption significantly
- Variable-speed ECM blower motor adapts to load conditions, improving comfort and efficiency
- Compact A-coil design fits tight attic and crawlspace installations where standard upflow units won't work
- PVC flue compatibility simplifies venting and reduces installation costs versus metal flue requirements
- R454B refrigerant with 14 SEER rating meets current efficiency standards without requiring retrofits
Cons
- 14 SEER1 rating is respectable but not best-in-class, missing out on newer 16+ SEER units available from competitors
- Single-stage condenser limits cooling efficiency compared to two-stage or variable-capacity systems
- 75 dB noise level sits at the louder end, potentially audible in finished basement installations
- No Energy Star certification despite strong AFUE rating suggests cooling side holds back overall efficiency recognition
Who Should Buy
Best For
Contractors retrofitting older homes where downflow configuration is mandatory, or builders working in tight attic spaces where standard 60-inch upflow units create installation headaches. Homeowners in moderate climates who prioritize heating efficiency and need reliable, straightforward equipment without premium pricing.
Consider Alternatives If
Buyers seeking cutting-edge cooling efficiency should look at newer 16 SEER units, and properties with existing two-stage or modulating cooling systems should match that capability rather than downgrading to single-stage.
Installation
Installation complexity stays moderate thanks to standard 3/8-inch liquid and 7/8-inch suction line sizing. The 208/230V single-phase requirement fits most residential panels, though the 32.8 to 50-amp breaker range demands proper circuit capacity planning. PVC flue venting simplifies ductwork compared to traditional metal, reducing material costs. Downflow/horizontal configuration means careful placement in attics or basements to maintain proper refrigerant flow and blower discharge direction.
Warranty & Reliability
The 10-year parts warranty, activated by online registration, provides solid baseline coverage standard in the industry. Registration is mandatory to unlock the warranty, so don't skip that step after installation. Coverage applies to compressor, blower motor, and heat exchanger, protecting against factory defects during the critical first decade of operation.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 60,000 |
| Heating BTU | 100,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| AHRI Certificate Number | 7424272 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Energy Star | No |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 50 amps |
| Min. Breaker Size | 32.8 amps |
| Tonnage | 5 Ton |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |