Independent Review · Updated June 2026

5 Ton 14 SEER Goodman Air Conditioner with Vertical 21" Uncased Coil

Solid 5-ton coil option with R454B efficiency and straightforward installation

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
5 Ton 14 SEER Goodman Air Conditioner with Vertical 21
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ 5-ton coil works best for contractors installing Goodman systems in homes requiring 60,000 BTU cooling capacity with R454B refrigerant compatibility. The 14 SEER1 rating and vertical A-coil design make it a smart choice for upflow or downflow installations where space efficiency matters.

Review

The ACiQ 5-ton vertical A-coil sits squarely in the middle of the residential cooling market. Designed specifically for Goodman system integration, this unit delivers 60,000 BTU cooling capacity with R454B refrigerant, meeting modern environmental standards. The vertical configuration stands 38.25 inches tall and 35.5 inches wide, making it practical for upflow and downflow installations. At 120 pounds, it's manageable for two technicians and arrives pre-assembled, reducing jobsite complexity.

Performance metrics reveal a competent mid-range cooling solution. The 14 SEER1 efficiency rating provides good seasonal cooling without the premium cost of 16+ SEER units. A scroll compressor handles single-stage operation, meaning it runs at full load or cycles off, which is straightforward but less nuanced than variable-speed alternatives. The 75 dBA sound level is typical for standard equipment, though quieter options exist. Electrical requirements are modest at 208/230V single-phase 60 Hz with 32.8 to 50 amp breaker sizing, fitting most residential panels.

Pros & Cons

Pros

  • 14 SEER1 efficiency rating delivers solid cooling performance for mid-range residential applications
  • R454B refrigerant provides future-proofed compliance with EPA standards and lower environmental impact
  • Vertical A-coil design at 38.25 inches tall fits tight spaces compared to horizontal alternatives
  • Simple scroll compressor technology means fewer moving parts and lower maintenance burden
  • 10-year warranty with online registration offers reasonable protection for homeowner peace of mind

Cons

  • 14 SEER1 falls behind higher-efficiency competitors offering 16-18 SEER ratings for similar tonnage
  • Single-stage compressor operates at full capacity or off, reducing part-load efficiency and comfort
  • 75 dBA noise level ranks above quieter variable-speed units that homeowners notice less

Who Should Buy

Best For

Budget-conscious homeowners and contractors replacing older systems who prioritize reliable cooling over maximum efficiency. This coil pairs well with Goodman condensers for new builds or retrofits where R454B compatibility is required.

Consider Alternatives If

Anyone seeking ENERGY STAR certification, high-SEER performance, or variable-capacity operation should explore 16+ SEER alternatives from competitors.

5 Ton 14 SEER Goodman Air Conditioner with Vertica
$0
Buy at HVACDirect →

Installation

Installation follows standard practices for vertical A-coils. The 3/8 inch liquid line and 7/8 inch suction line connect to compatible Goodman condensers using provided fittings. Suction line insulation at 3/8 inch thickness is included for the standard 30-foot run. Technicians should reference the Goodman Installation Manual and Service Instructions for proper charging and evacuation procedures. Mounting brackets and kit components require assembly per included documentation.

Warranty & Reliability

ACiQ offers 10 years of parts coverage when registered online, a solid protection level for residential coils. This covers manufacturing defects and component failures, though does not include labor costs. Online registration must be completed within 90 days to activate full coverage. For contractors, verify that your labor warranty extension is available separately, as the manufacturer warranty covers parts only.

Specifications

SKUACIQ-60-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU60,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)75
Weight (in lbs)120.000000
FeatureSpec
ConfigurationUpflow / Downflow
Liquid Line3/8"
Suction Line7/8"
Tonnage5 Ton
StyleA-Coil
Height38.25"
Width35.5"
Depth35.5"
ResourcesGoodman Installation Manual Goodman Specifications Goodman Brochure Goodman Warranty Information Goodman Service Instructions Goodman Kit Instructions Goodman Parts Manual You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
Energy StarNo
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Max Breaker Size50 amps
Min. Breaker Size32.8 amps
Suction Line Insulation Thickness3/8"
Length30 feet

Frequently Asked Questions

Can this coil work with non-Goodman condensers? +
ACiQ designed this unit specifically for Goodman system compatibility. While line sizes and refrigerant type (R454B) may match competitors, optimal performance and warranty protection require pairing with Goodman condensers. Using mismatched components voids coverage.
What's the difference between upflow and downflow configuration? +
Both use the same vertical A-coil design. Upflow mounts in basements or crawl spaces with air rising through the coil, while downflow sits in attics with air falling. Airflow direction depends on your furnace placement and ductwork layout, not the coil itself.
How does 14 SEER1 compare to newer ratings? +
SEER1 replaced legacy SEER ratings in 2023 and typically runs 15-20% lower numerically. This 14 SEER1 unit approximates an older 16-17 SEER model. It's efficient for its class but trails premium units offering 18+ SEER1 and variable-speed operation.
Is R454B refrigerant better than R410A? +
R454B is EPA's approved lower-GWP replacement for R410A, meaning reduced environmental impact. Performance is virtually identical, and charging procedures are similar. New EPA rules favor R454B, making this coil future-compliant and protected from potential R410A phase-out restrictions.
Does the 10-year warranty cover labor? +
No, the 10-year coverage applies to parts only. Labor, service calls, and refrigerant are your responsibility. Extended service plans available through installers can cover these costs, so ask your contractor about add-on protection options.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.