Review
Goodman's 5-ton upflow system represents the practical middle ground in HVAC replacement. At $2,071, it undercuts premium brands while delivering 80,000 BTU heating capacity and 54,000 BTU cooling in a compact 30-inch-tall cabinet. The A-coil configuration, variable-speed blower, and dual-stage furnace appeal to contractors who value straightforward installation and homeowners watching their budget. This unit occupies the tier where most replacements happen: above builder-grade equipment but below high-efficiency systems.
Performance specs tell a mixed efficiency story. The 80% AFUE furnace is respectable but trails modern 95% units by roughly 15 percentage points in heating conversion. The 15 SEER cooling rating (16 SEER1 measured under newer standards) handles moderate load homes adequately, though single-stage operation means no capacity modulation. The variable-speed blower running up to 2000 CFM helps distribute air more evenly than fixed-speed motors. Real-world heating costs will depend on propane versus natural gas pricing and local winter severity.
Pros & Cons
Pros
- 80% AFUE furnace with dual-stage burners reduces heating costs compared to 70-75% units, especially in heating-dominant climates
- 15 SEER cooling (or 16 SEER1 per specs) qualifies for ENERGY STAR and matches mid-tier efficiency expectations
- Variable-speed blower motor (2000 CFM max) provides better comfort control and quieter operation than single-speed alternatives
- Two-stage heating and single-stage cooling simplify maintenance and reduce component failure risk
- 10-year warranty with online registration offers solid protection for the investment
Cons
- 80% AFUE is outdated compared to 95%+ AFUE units now available, missing high-efficiency rebates in many regions
- 73 dBA noise level is noticeably louder than premium variable-capacity systems, which run 65-68 dBA
- Single-stage cooling cannot modulate capacity, wasting energy on oversized load days in mild weather
Who Should Buy
Best For
Homeowners replacing 25+ year old furnaces in climates with genuine winter heating needs, or contractors serving price-sensitive customers who prioritize upfront cost over long-term utility savings. This system makes sense where heating dominates the annual load.
Consider Alternatives If
Anyone in mild climates (South, Southwest) where cooling dominates, or buyers who plan to stay in their home 15+ years and want efficiency rebates. Upgrading to 95% AFUE will pay back faster in northern regions.
Installation
Upflow configuration suits basements and crawl spaces where the unit sits below ductwork. The 208/230V single-phase electrical requirement needs 29.6 to 50 amp breaker sizing, standard for most homes. Metal flue exhaust ducting is mandatory. Liquid and suction lines use standard 3/8-inch and 1 1/8-inch copper with 1/2-inch suction insulation included. Weight at 48 pounds makes solo installation manageable but team installation reduces injury risk.
Warranty & Reliability
The 10-year warranty requires online registration and covers parts against defects. This duration is industry standard and provides reasonable financial protection for a $2,071 unit. However, coverage typically excludes labor, refrigerant, and damage from improper installation. Extended warranties are usually available through retailers, though cost-benefit depends on installer reputation and local repair prices.
Specifications
| SKU | LS381183850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 54,000 |
| Heating BTU | 80,000 |
| Refrigerant | R410A |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 73 |
| Weight (in lbs) | 48.000000 |
| Feature | Spec |
| AHRI Certificate Number | 204633307 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 30" |
| Width | 24.5" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 50 amps |
| Min. Breaker Size | 29.6 amps |
| Tonnage | 5 Ton |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions