Review
Goodman positions this 5-ton gas furnace and air conditioner combo as the practical choice for residential applications prioritizing efficiency without premium pricing. The CAPT4961D4 targets contractors and homeowners seeking a split system that handles upflow installations cleanly. With a 96% AFUE furnace paired to a 16 SEER2 condenser, this unit occupies solid middle ground in the market, balancing performance, cost, and installation straightforwardness that contractors appreciate.
The furnace delivers 120,000 BTU of heating output at 96% AFUE, meaning minimal fuel waste on winter heating calls. Cooling capacity reaches 60,000 BTU at 16 SEER2 efficiency, adequate for most residential zones. Two-stage burner and compressor design allow modulation rather than on-off cycling, reducing temperature swings and humidity issues. The ECM multi-speed blower motor adjusts CFM up to 2000 based on demand, lowering energy consumption versus fixed-speed alternatives. PVC flue compatibility and right-sided flue location make retrofits and new construction installations faster than traditional metal venting.
Pros & Cons
Pros
- 96% AFUE furnace delivers exceptional heating efficiency, reducing winter gas bills by 15-20% versus 80% AFUE models
- 16 SEER2 cooling efficiency is competitive for a 5-ton unit, translating to lower summer electricity costs
- Two-stage burner and two-stage compressor provide modulating comfort and quieter operation at part load
- ECM multi-speed blower motor adjusts airflow intelligently, improving humidity control and reducing energy waste
- PVC exhaust flue requirement simplifies installation and reduces venting material costs compared to metal alternatives
Cons
- 75 dB noise level puts this unit at the louder end of residential HVAC, noticeable during operation
- Entry-level Goodman brand lacks the reputation premium manufacturers command, though reliability is solid
- 16 SEER2 lags high-efficiency models hitting 18-20 SEER2, leaving efficiency gains on the table in hot climates
Who Should Buy
Best For
Homeowners replacing aging equipment in moderate climates where 96% AFUE heating efficiency provides the strongest ROI. Contractors standardizing on Goodman split systems for cost-conscious customers who value balanced performance and straightforward upflow installation.
Consider Alternatives If
Buyers in extreme heat climates seeking maximum cooling efficiency or those prioritizing whisper-quiet operation should explore premium brands with higher SEER2 ratings and lower decibel levels.
Installation
This upflow coil mounts vertically at 30 inches tall, 24.5 inches wide, and 21 inches deep, fitting standard utility closets and basements. PVC plastic exhaust flue eliminates complex metal ductwork routing. Electrical service requires 208/230V single-phase 60 Hz with 37.2 to 60 amp breaker, straightforward for most homes. Sweat valve connections and 3/8-inch and 7/8-inch line sets standardize refrigerant work. Installation time typically runs 4-6 hours for experienced HVAC technicians.
Warranty & Reliability
Goodman provides a 10-year limited warranty on parts and labor when registered online within 60 days of installation. Registration extends coverage significantly beyond the standard one-year parts warranty. This 10-year umbrella covers compressor, heat exchanger, and coil defects, offering solid protection for system failures. Missing registration voids extended coverage, so contractors must document registration as part of final commissioning.
Specifications
| SKU | CAPT4961D4 |
| Brand/Manufacturer | Goodman |
| Cooling BTU | 60,000 |
| Heating BTU | 120,000 |
| Refrigerant | R410A |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 76.000000 |
| Feature | Spec |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Multi-Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Energy Star | Yes |
| Burner Stages | Two |
| Fuel Type | Gas |
| Height | 30" |
| Width | 24.5" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Two Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 60 amps |
| Min. Breaker Size | 37.2 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |