Independent Review · Updated June 2026

5 Ton 15 SEER 96% AFUE 120,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow

96% AFUE furnace meets 16 SEER2 cooling in a straightforward, contractor-friendly package

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
5 Ton 15 SEER 96% AFUE 120,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This Goodman system excels for homeowners in moderate climates needing dependable heating and cooling without premium pricing. It's ideal for contractors installing split systems in upflow applications where PVC venting is available and budget matters.

Review

Goodman positions this 5-ton gas furnace and air conditioner combo as the practical choice for residential applications prioritizing efficiency without premium pricing. The CAPT4961D4 targets contractors and homeowners seeking a split system that handles upflow installations cleanly. With a 96% AFUE furnace paired to a 16 SEER2 condenser, this unit occupies solid middle ground in the market, balancing performance, cost, and installation straightforwardness that contractors appreciate.

The furnace delivers 120,000 BTU of heating output at 96% AFUE, meaning minimal fuel waste on winter heating calls. Cooling capacity reaches 60,000 BTU at 16 SEER2 efficiency, adequate for most residential zones. Two-stage burner and compressor design allow modulation rather than on-off cycling, reducing temperature swings and humidity issues. The ECM multi-speed blower motor adjusts CFM up to 2000 based on demand, lowering energy consumption versus fixed-speed alternatives. PVC flue compatibility and right-sided flue location make retrofits and new construction installations faster than traditional metal venting.

Pros & Cons

Pros

  • 96% AFUE furnace delivers exceptional heating efficiency, reducing winter gas bills by 15-20% versus 80% AFUE models
  • 16 SEER2 cooling efficiency is competitive for a 5-ton unit, translating to lower summer electricity costs
  • Two-stage burner and two-stage compressor provide modulating comfort and quieter operation at part load
  • ECM multi-speed blower motor adjusts airflow intelligently, improving humidity control and reducing energy waste
  • PVC exhaust flue requirement simplifies installation and reduces venting material costs compared to metal alternatives

Cons

  • 75 dB noise level puts this unit at the louder end of residential HVAC, noticeable during operation
  • Entry-level Goodman brand lacks the reputation premium manufacturers command, though reliability is solid
  • 16 SEER2 lags high-efficiency models hitting 18-20 SEER2, leaving efficiency gains on the table in hot climates

Who Should Buy

Best For

Homeowners replacing aging equipment in moderate climates where 96% AFUE heating efficiency provides the strongest ROI. Contractors standardizing on Goodman split systems for cost-conscious customers who value balanced performance and straightforward upflow installation.

Consider Alternatives If

Buyers in extreme heat climates seeking maximum cooling efficiency or those prioritizing whisper-quiet operation should explore premium brands with higher SEER2 ratings and lower decibel levels.

5 Ton 15 SEER 96% AFUE 120,000 BTU Goodman Gas Fur
$0
Buy at HVACDirect →

Installation

This upflow coil mounts vertically at 30 inches tall, 24.5 inches wide, and 21 inches deep, fitting standard utility closets and basements. PVC plastic exhaust flue eliminates complex metal ductwork routing. Electrical service requires 208/230V single-phase 60 Hz with 37.2 to 60 amp breaker, straightforward for most homes. Sweat valve connections and 3/8-inch and 7/8-inch line sets standardize refrigerant work. Installation time typically runs 4-6 hours for experienced HVAC technicians.

Warranty & Reliability

Goodman provides a 10-year limited warranty on parts and labor when registered online within 60 days of installation. Registration extends coverage significantly beyond the standard one-year parts warranty. This 10-year umbrella covers compressor, heat exchanger, and coil defects, offering solid protection for system failures. Missing registration voids extended coverage, so contractors must document registration as part of final commissioning.

Specifications

SKUCAPT4961D4
Brand/ManufacturerGoodman
Cooling BTU60,000
Heating BTU120,000
RefrigerantR410A
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)75
Weight (in lbs)76.000000
FeatureSpec
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE96%
Blower MotorMulti-Speed - ECM
Maximum CFM2000
ConfigurationUpflow / Downflow
Flue LocationRight
Energy StarYes
Burner StagesTwo
Fuel TypeGas
Height30"
Width24.5"
Depth21"
ResourcesCAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
SEER1 (Efficiency)16
Condenser StagesTwo Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Max Breaker Size60 amps
Min. Breaker Size37.2 amps
Tonnage5 Ton
Valve TypeSweat
Liquid Line3/8"
Suction Line7/8"
StyleA-Coil

Frequently Asked Questions

How does 96% AFUE compare to my current furnace? +
If your furnace is 10-15 years old, it likely operates at 80-85% AFUE, wasting 15-20% of fuel energy. Upgrading to 96% AFUE cuts heating fuel consumption by roughly 15-20%, saving $300-600 annually on natural gas depending on climate and usage patterns. Payback typically occurs within 5-7 years.
Is this unit compatible with my existing ductwork? +
Yes, the 5-ton capacity with 2000 CFM maximum airflow matches standard residential ductwork designed for similar tonnage. Upflow configuration requires ductwork above the unit. Have your HVAC contractor verify existing ducts are clean and properly sealed to avoid efficiency loss and performance issues.
Why is 16 SEER2 lower than newer high-efficiency systems? +
16 SEER2 represents solid efficiency without premium components or inverter technology. Systems reaching 18-20 SEER2 use variable-speed compressors and advanced controls, adding $1500-3000 to cost. In moderate climates, 16 SEER2 offers excellent ROI. In extreme heat zones, premium efficiency justifies higher investment.
Should I choose this over a Lennox or Trane system? +
Premium brands offer longer warranties and slightly higher efficiency ratings. Goodman delivers 95% of their performance at 70-80% of their price point. For budget-conscious buyers prioritizing reliability over brand prestige, Goodman performs admirably. Contractors often recommend this combo for value-oriented customers.
What does the 10-year warranty actually cover? +
Online registration extends the warranty to 10 years on parts including the compressor, heat exchanger, and coil. It covers manufacturing defects, not wear items or misuse. Labor coverage varies by installer and location. Always confirm registration completion before the 60-day deadline to activate extended protection.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.