Review
The Goodman CAPT4961C4 is a no-nonsense dual-fuel system combining a 100,000 BTU furnace and 60,000 BTU air conditioner into a single upflow unit. It targets cost-conscious homeowners and contractors who need dependable performance without premium brand markup. At 5 tons and 21x21x30 inches, it fits standard equipment closets and basement installations. The Energy Star badge confirms it meets federal efficiency minimums, while the modulating burner and two-stage compressor suggest Goodman balanced efficiency with part-load flexibility.
Heating performance anchors this system. The 97% AFUE rating with modulating burners means the furnace fires at lower stages during mild weather, reducing on-off cycling and gas consumption compared to single-stage units. On cooling, the 16 SEER2 rating and variable-speed ECM blower deliver solid seasonal performance without oversizing. The scroll compressor and 3/8 inch liquid line are industry standard for 5-ton units. Maximum CFM of 2,000 matches the 5-ton capacity, and support for both natural gas and propane adds flexibility for rural and urban installations.
Pros & Cons
Pros
- 97% AFUE heating efficiency with modulating burners, meaning lower gas consumption and less temperature swing
- 16 SEER2 cooling rating (advertised as 15 SEER), two-stage compressor, and R410A refrigerant for reliable summer performance
- Variable-speed ECM blower motor maximizes comfort by ramping output to match actual demand, reducing noise and energy waste
- Energy Star certified with PVC/plastic flue compatibility, simplifying retrofit installations in many older homes
- 10-year warranty with online registration, covering parts and labor across the entire system
Cons
- 75 dBA operating noise is moderately loud, not ideal for noise-sensitive installations near bedrooms
- Requires 208/230V single-phase power, limiting compatibility in some older homes with only 120V service
- No pricing listed here, but Goodman systems typically cost less than mid-tier brands, which may signal lower-cost components in some subsystems
Who Should Buy
Best For
Homeowners in heating-dominant climates upgrading from 80-90% AFUE furnaces will see the biggest ROI, recovering equipment costs through reduced gas bills within 5-7 years. Contractors valuing straightforward installations and solid warranty backing will appreciate the upflow configuration, variable-speed blower, and PVC flue option.
Consider Alternatives If
Buyers in all-cooling climates should prioritize higher-tonnage AC units. Those with 120V service only or homes where noise matters most should evaluate quieter, higher-SEER alternatives.
Installation
Upflow configuration suits basement and closet installations with right-side flue exit. PVC/plastic flue compatibility reduces venting costs compared to metal ductwork. Variable-speed ECM blower requires 208/230V single-phase 60Hz power at 37.2 to 60 amps depending on stage. Refrigerant lines use 3/8 inch suction and 7/8 inch discharge with sweat connections, standard for skilled HVAC technicians. Most installations take 4-6 hours for experienced crews.
Warranty & Reliability
Goodman covers parts and labor for 10 years when you register the unit online within 30 days of purchase. This warranty is transferable if you sell the home, adding resale value. Coverage includes the compressor, blower motor, and heat exchanger, the most expensive failure points. Online registration is straightforward and instantly activates coverage.
Specifications
| SKU | CAPT4961C4 |
| Brand/Manufacturer | Goodman |
| Cooling BTU | 60,000 |
| Heating BTU | 100,000 |
| Refrigerant | R410A |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 73.000000 |
| Feature | Spec |
| AHRI Certificate Number | 7424267 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Energy Star | Yes |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Two Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 60 amps |
| Min. Breaker Size | 37.2 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |