Review
The Goodman 5-ton horizontal furnace and air conditioner system occupies the sensible middle ground of the residential HVAC market. At this price point and efficiency tier, it competes directly with Carrier, Lennox, and Armstrong equipment but differentiates through straightforward engineering and honest performance ratings. The horizontal A-coil design makes it particularly valuable for tight installations where vertical clearance becomes the limiting factor.
Heating performance reaches 120,000 BTU with a two-stage burner and exceptional 96% AFUE efficiency, meaning 96 cents of every fuel dollar converts to home warmth. On the cooling side, the system delivers 57,000 BTU with two-stage compressor modulation and scroll compression technology. The variable-speed ECM blower motor rated at 2000 CFM maximum adapts to heating and cooling cycles, improving comfort and reducing unnecessary run time compared to older single-speed equipment.
Pros & Cons
Pros
- 96% AFUE furnace efficiency minimizes heating fuel waste and reduces monthly utility bills substantially
- Two-stage compressor and condenser allow variable cooling capacity, matching load demands and cutting runtime costs
- Variable-speed ECM blower motor improves air distribution and reduces energy consumption versus fixed-speed alternatives
- Horizontal configuration suits tight attic, crawlspace, or utility closet installations common in residential retrofits
- 10-year warranty with online registration covers parts and provides reasonable protection for the investment
Cons
- SEER ratings show 18 cooling efficiency on specs but product title lists 16 SEER, creating labeling confusion
- 74 dB noise level runs slightly louder than premium systems, noticeable in quiet settings or bedrooms near equipment
- R410A refrigerant compatibility only on most units, limiting retrofit options for older R22 systems without coil replacement
Who Should Buy
Best For
Homeowners upgrading 15+ year old systems in moderate climate zones who prioritize heating efficiency and want reliable two-stage cooling without luxury pricing. Contractors valuing straightforward installation in tight spaces appreciate the horizontal configuration and proven Goodman components.
Consider Alternatives If
Buyers in very hot climates seeking maximum cooling performance or homeowners with existing R22 systems wanting a direct retrofit should explore higher-SEER alternatives or models with better refrigerant flexibility.
Installation
Installation requires standard 208/230V single-phase 60 Hz service with breaker sizing between 36.7 and 60 amps depending on local code. The horizontal orientation demands proper support, typically in attics or above crawlspaces with adequate return air clearance. Plastic PVC exhaust flue simplifies venting compared to metal duct systems. Refrigerant lines use standard 3/8 inch liquid and 7/8 inch suction connections with sweat valve fittings.
Warranty & Reliability
Goodman provides a standard 10-year comprehensive parts warranty when you register online after purchase. Coverage includes compressor, control boards, and the furnace heat exchanger during the full term. This warranty aligns with industry standards for mid-tier equipment and offers reasonable protection, though premium manufacturers sometimes extend coverage to 12 years.
Specifications
| SKU | CHPF4860D6 |
| Brand/Manufacturer | Goodman |
| Cooling BTU | 57,000 |
| Heating BTU | 120,000 |
| Refrigerant | R410A or R22 |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 77.000000 |
| Feature | Spec |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368842 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Horizontal |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 24.5" |
| Width | 26" |
| Depth | 21.125" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| SEER1 (Efficiency) | 18 |
| Condenser Stages | Two Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 60 amps |
| Min. Breaker Size | 36.7 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
Frequently Asked Questions