Review
The Goodman GPDM3 represents mainstream dual-fuel thinking, pairing a heat pump with natural gas backup for markets where winter heating is significant enough to justify the investment. At 3 tons cooling capacity and 80,000 BTU heating output, it addresses the gap between pure electric heat pumps and traditional gas furnaces. The 13.4 SEER2 rating positions it solidly in today's efficiency baseline, while the $5,262 price keeps it accessible to residential contractors managing customer budgets.
Performance metrics show a competent but not exceptional unit. The 13.4 SEER2 cooling efficiency translates to roughly 1,200 maximum CFM with the 5-speed EEM blower motor, running at 76 dB from a single-stage scroll compressor. The 8.0 HSPF heat pump rating handles spring and fall transitions well, though the 80% AFUE gas furnace is purely functional, not cutting-edge. With 208/230V single-phase power and 40-amp maximum breaker sizing, installation fits standard residential electrical without major upgrades.
Pros & Cons
Pros
- 13.4 SEER2 rating delivers solid cooling efficiency, roughly 30% better than 10 SEER equipment from a decade ago
- 80,000 BTU heating capacity with two-stage gas burner handles cold climates better than heat pump alone
- Pre-charged with 124 oz R410A refrigerant reduces installation labor and potential leak points
- 5-speed EEM blower motor optimizes airflow and reduces runtime noise at 76 dB
- Direct drive scroll compressor is proven design with fewer moving parts than reciprocating alternatives
Cons
- Single-stage cooling compressor means it runs full blast or off, no modulation for mild weather efficiency
- Controller not included, requiring separate purchase and adds to total project cost
- 80% AFUE furnace is baseline efficiency, modern units push 95% AFUE
- 76 dB noise level is louder than high-end competitors, noticeable to neighbors in quiet areas
Who Should Buy
Best For
Contractors installing systems in moderate climates where dual-fuel makes economic sense, and homeowners replacing aging 10-13 SEER equipment on a realistic budget. This works well in zones where winter heating is needed 3-4 months yearly.
Consider Alternatives If
Anyone in consistently cold climates needing maximum heating efficiency should look at 95+ AFUE furnaces, and customers bothered by outdoor unit noise should audition quieter models around 72-73 dB.
Installation
Pre-charged refrigerant is a genuine time-saver, eliminating field charging complexity and reducing commissioning from hours to minutes. Downflow/horizontal configuration suits basement or closet placement. You'll need a 25 to 40-amp dedicated circuit, standard for most homes. The 440-pound weight requires two technicians or mechanical lift assistance. Controller comes separate, so factor an additional controller purchase into project budgeting.
Warranty & Reliability
Ten-year parts coverage with online registration is competitive for this price tier, matching or beating most Goodman competitors. Coverage includes compressor, heat exchanger, and blower assembly defects. Registration is straightforward online. Note that labor is not covered, and voiding can occur with improper installation or failure to maintain filter changes per manual specifications.
Specifications
| SKU | GPDM33608041 |
| Brand/Manufacturer | Goodman |
| Cooling BTU | 34,000 BTU |
| Heating BTU | 80,000 BTU |
| Refrigerant | R410A |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 76 dB |
| Weight (in lbs) | 440.000000 |
| Feature | Spec |
| Refrigerant Charge | 124 Oz |
| AHRI Certificate Number | 209319582 |
| Replaces | GPD1436080M41 |
| Controller | Not Included |
| Additional Information | Pre-Charged for Easy Installation |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | 5 Speed EEM |
| Drive Type | Direct |
| Maximum CFM | 1,200 |
| Motor RPM | 880 |
| Horsepower | 1/2 |
| Configuration | Downflow/Horizontal |
| Efficiency | 81% |
| HSPF | 8.0 |
| SEER2 (Efficiency) | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Max Breaker Size | 40 Amps |
| Min. Breaker Size | 25 Amps |
| Tonnage | 3 Ton |
| Low NOx | Low NOx |
| Burner Stages | Two |
| Fuel Type | Natural Gas |
| Height | 34 1/2" |
| Width | 47" |
| Depth | 51" |
| Location | Outdoor |
| Resources | GPDM3 Installation Manual GPDM3 Specifications Sheet GPDM3 Replacement Parts Manual GPDM3 Service Manual Goodman Packaged Unit Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.