Independent Review · Updated June 2026

3 Ton 13.4 SEER2 80,000 BTU Goodman Dual Fuel Heat Pump and Gas Package Unit

Solid dual-fuel workhorse with 13.4 SEER2 efficiency and reasonable price point.

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
3 Ton 13.4 SEER2 80,000 BTU Goodman Dual Fuel Heat Pump and Gas Package Unit
Current Price
$5262
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This unit is built for contractors and homeowners in mixed climates who need dependable heating and cooling without premium pricing. The 13.4 SEER2 rating and 8.0 HSPF mean you'll see real energy savings compared to older equipment, especially in regions where you run both heat pump and gas furnace modes regularly.

Review

The Goodman GPDM3 represents mainstream dual-fuel thinking, pairing a heat pump with natural gas backup for markets where winter heating is significant enough to justify the investment. At 3 tons cooling capacity and 80,000 BTU heating output, it addresses the gap between pure electric heat pumps and traditional gas furnaces. The 13.4 SEER2 rating positions it solidly in today's efficiency baseline, while the $5,262 price keeps it accessible to residential contractors managing customer budgets.

Performance metrics show a competent but not exceptional unit. The 13.4 SEER2 cooling efficiency translates to roughly 1,200 maximum CFM with the 5-speed EEM blower motor, running at 76 dB from a single-stage scroll compressor. The 8.0 HSPF heat pump rating handles spring and fall transitions well, though the 80% AFUE gas furnace is purely functional, not cutting-edge. With 208/230V single-phase power and 40-amp maximum breaker sizing, installation fits standard residential electrical without major upgrades.

Pros & Cons

Pros

  • 13.4 SEER2 rating delivers solid cooling efficiency, roughly 30% better than 10 SEER equipment from a decade ago
  • 80,000 BTU heating capacity with two-stage gas burner handles cold climates better than heat pump alone
  • Pre-charged with 124 oz R410A refrigerant reduces installation labor and potential leak points
  • 5-speed EEM blower motor optimizes airflow and reduces runtime noise at 76 dB
  • Direct drive scroll compressor is proven design with fewer moving parts than reciprocating alternatives

Cons

  • Single-stage cooling compressor means it runs full blast or off, no modulation for mild weather efficiency
  • Controller not included, requiring separate purchase and adds to total project cost
  • 80% AFUE furnace is baseline efficiency, modern units push 95% AFUE
  • 76 dB noise level is louder than high-end competitors, noticeable to neighbors in quiet areas

Who Should Buy

Best For

Contractors installing systems in moderate climates where dual-fuel makes economic sense, and homeowners replacing aging 10-13 SEER equipment on a realistic budget. This works well in zones where winter heating is needed 3-4 months yearly.

Consider Alternatives If

Anyone in consistently cold climates needing maximum heating efficiency should look at 95+ AFUE furnaces, and customers bothered by outdoor unit noise should audition quieter models around 72-73 dB.

3 Ton 13.4 SEER2 80,000 BTU Goodman Dual Fuel Heat
$5262
Buy at HVACDirect →

Installation

Pre-charged refrigerant is a genuine time-saver, eliminating field charging complexity and reducing commissioning from hours to minutes. Downflow/horizontal configuration suits basement or closet placement. You'll need a 25 to 40-amp dedicated circuit, standard for most homes. The 440-pound weight requires two technicians or mechanical lift assistance. Controller comes separate, so factor an additional controller purchase into project budgeting.

Warranty & Reliability

Ten-year parts coverage with online registration is competitive for this price tier, matching or beating most Goodman competitors. Coverage includes compressor, heat exchanger, and blower assembly defects. Registration is straightforward online. Note that labor is not covered, and voiding can occur with improper installation or failure to maintain filter changes per manual specifications.

Specifications

SKUGPDM33608041
Brand/ManufacturerGoodman
Cooling BTU34,000 BTU
Heating BTU80,000 BTU
RefrigerantR410A
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)76 dB
Weight (in lbs)440.000000
FeatureSpec
Refrigerant Charge124 Oz
AHRI Certificate Number209319582
ReplacesGPD1436080M41
ControllerNot Included
Additional InformationPre-Charged for Easy Installation
Furnace Efficiency / AFUE80%
Blower Motor5 Speed EEM
Drive TypeDirect
Maximum CFM1,200
Motor RPM880
Horsepower1/2
ConfigurationDownflow/Horizontal
Efficiency81%
HSPF8.0
SEER2 (Efficiency)13.4
Condenser StagesSingle Stage
Compressor TypeScroll
Max Breaker Size40 Amps
Min. Breaker Size25 Amps
Tonnage3 Ton
Low NOxLow NOx
Burner StagesTwo
Fuel TypeNatural Gas
Height34 1/2"
Width47"
Depth51"
LocationOutdoor
ResourcesGPDM3 Installation Manual GPDM3 Specifications Sheet GPDM3 Replacement Parts Manual GPDM3 Service Manual Goodman Packaged Unit Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.

Frequently Asked Questions

What does 13.4 SEER2 really mean in my monthly bill? +
SEER2 reflects real-world cooling at high outdoor temps. At 13.4 SEER2, you're using roughly 30% less electricity than a 10 SEER unit from 2010. Monthly savings depend on your local climate and usage, but a Texas homeowner might see $15-25 monthly reductions versus older equipment during peak summer.
Do I need an external controller, and what will it cost? +
Yes, this unit ships without a thermostat or control board. You'll need a compatible Goodman or universal dual-fuel controller, running $400-800 installed depending on features. Budget this as a separate line item before purchase to avoid surprises.
How does 8.0 HSPF heating compare to a traditional furnace? +
The 8.0 HSPF heat pump mode is efficient in 35-50 degree weather but weak below 20 degrees. That's why the 80% AFUE gas furnace kicks in during winter. In moderate climates, you'll run heat pump mode 60-70% of heating season, saving substantially on gas costs.
Is Goodman reliability solid compared to Carrier or Lennox? +
Goodman scroll compressors have proven track records in commercial and residential work. They're not premium, but breakdowns are uncommon within the five-year warranty overlap period. Expect similar lifespans to mid-tier Carrier or Lennox units, usually 12-15 years with proper maintenance.
What happens if the compressor fails after year 5? +
Parts are covered under the 10-year warranty, but out-of-pocket labor can run $2,000-3,000 for compressor replacement. Consider extended service contracts if longevity beyond 10 years is important to you.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.