Review
The Goodman 1.5-ton gas furnace and heat pump system represents solid mid-market equipment that balances efficiency and affordability. This downflow A-coil unit pairs a 60,000 BTU furnace with 18,000 BTU cooling capacity, making it suitable for homes in the 1,200-1,500 square foot range. At $2,466, it undercuts many comparable systems while maintaining ENERGY STAR certification. The unit pulls specs from the GSZ140191 lineage, proven equipment with established service networks.
Performance metrics impress for the price point. The furnace delivers 96% AFUE efficiency, meaning 96 cents of every heating dollar converts to usable heat. The 14 SEER cooling rating trails premium units at 16-18 SEER but beats baseline 13 SEER equipment by roughly 8 percent. The variable-speed ECM blower motor adapts to actual heating and cooling loads, reducing energy waste during partial-load operation. Two-stage burner technology lets the furnace run at reduced capacity in mild weather, cutting unnecessary fuel consumption and improving efficiency.
Pros & Cons
Pros
- 96% AFUE furnace efficiency means lower heating costs, about 4% better than 92% baseline models
- 14 SEER cooling rating qualifies for ENERGY STAR and utility rebates, reducing out-of-pocket cost
- Dual-fuel capability with propane and natural gas gives flexibility for different regions and situations
- Variable-speed ECM blower motor adjusts to actual demand, improving comfort and efficiency
- Two-stage burner allows lower heating output in mild weather, reducing cycling and energy waste
- $2,466 price point undercuts comparable 1.5-ton systems by $400-600
Cons
- Single-stage compressor means the cooling system runs at full capacity even for partial loads, less efficient than two-stage alternatives
- 70 dBA noise level is moderate to loud, particularly noticeable in quiet neighborhoods or for sound-sensitive homeowners
- Downflow configuration limits placement options, requiring basement or crawlspace installation
Who Should Buy
Best For
Homeowners replacing aging furnace-only systems or looking to add heat pump cooling should consider this unit, especially those in climates with moderate heating and cooling demands. The combination of strong AFUE and SEER ratings makes sense for mid-range budgets where efficiency rebates matter.
Consider Alternatives If
Buyers in extreme climates, those needing two-stage compressor technology for variable-load efficiency, or anyone with tight installation spaces should explore alternative configurations.
Installation
This downflow unit requires basement or crawlspace mounting with proper ductwork configuration. The A-coil style integrates with existing furnace plenums. Installation demands 115V single-phase 60Hz electrical service with 11.8 to 20 amp breaker capacity, standard in most homes. Refrigerant lines use 3/8 inch liquid and 3/4 inch suction sizing with insulation, and gas lines accept natural gas or propane. PVC exhaust flue is required, simplifying venting versus metal duct systems.
Warranty & Reliability
Goodman includes a 10-year parts and labor warranty upon online registration, standard industry practice for mid-tier equipment. This covers compressor failure, heat exchanger cracks, and component defects. Registration is straightforward and extends coverage significantly beyond the base one-year warranty. Most contractors handle this during installation, but verify registration completion before equipment startup.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 18000 |
| Heating BTU | 60,000 |
| Refrigerant | R410A |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 70 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Replaces | GSZ140191 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 20 amps |
| Min. Breaker Size | 11.8 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Downflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| AHRI Certificate Number | 7368838 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.