Independent Review · Updated June 2026

2.5 Ton 14 SEER 80% AFUE 60,000 BTU Goodman Gas Furnace and Heat Pump System - Horizontal

Solid 2.5-ton split system balancing 14 SEER cooling with 80% AFUE heating

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2.5 Ton 14 SEER 80% AFUE 60,000 BTU Goodman Gas Furnace and Heat Pump System - Horizontal
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ unit works best for homeowners upgrading older two-stage gas furnaces who want meaningful cooling efficiency gains without premium pricing. The 14 SEER rating and two-stage gas burner deliver responsive performance in moderate climates where heating demand is significant.

Review

The ACiQ ACIQ-30-EHPD-UPG is a competent mid-tier packaged system combining a 2.5-ton heat pump with a two-stage gas furnace. This horizontal A-coil design targets contractors and homeowners replacing older split systems where space is limited. Its positioning sits between budget single-stage units and high-efficiency variable-speed models, making it a practical choice for cost-conscious replacements.

Performance specs show 30,000 BTU cooling capacity with 14 SEER rating, delivering solid efficiency for moderate climates. The furnace side produces 30,000 BTU heating output at 80% AFUE with dual burner stages, allowing some modulation below peak fire. The high-efficiency multi-speed blower reaches 1200 CFM maximum, supporting proper airflow distribution across typical residential ductwork.

Pros & Cons

Pros

  • 14 SEER cooling efficiency qualifies for ENERGY STAR and utility rebates, reducing operating costs
  • Two-stage burner on 80% AFUE furnace provides modulated heating, improving comfort during mild weather
  • High-efficiency multi-speed blower caps at 1200 CFM, enabling better ductwork matching and zoning
  • A-coil horizontal configuration works in tight attic or closet spaces where vertical units don't fit
  • R454B refrigerant is future-proof, not subject to phase-out restrictions like older blends

Cons

  • 80% AFUE furnace lags behind 95%+ AFUE condensing models by 15+ percentage points on heating efficiency
  • Single-stage condenser means the heat pump runs at full capacity continuously, missing part-load efficiency gains
  • 74 dB noise level is noticeably louder than premium units, particularly during full-load furnace operation

Who Should Buy

Best For

Contractors installing replacement systems in homes with existing gas lines and moderate winter climates will find strong value here. Homeowners who heat primarily with gas but want better summer cooling efficiency without replacing ductwork appreciate the straightforward upgrade path.

Consider Alternatives If

Skip this if you're in a cold climate where furnace heating dominates annual runtime, since the 80% AFUE limits year-round savings. Avoid if noise sensitivity is high or if your budget stretches to 16 SEER systems with variable-speed compressors.

2.5 Ton 14 SEER 80% AFUE 60,000 BTU Goodman Gas Fu
$0
Buy at HVACDirect →

Installation

Installation requires 208/230V single-phase power with a 30-amp breaker minimum and 18.7-amp minimum running current. The unit accepts 3/8 inch liquid and 3/4 inch suction lines with sweat connections, using R454B refrigerant. Metal exhaust flue is mandatory. Horizontal orientation simplifies attic placement where vertical clearance is constrained, though ductwork sizing to 1200 CFM maximum demands proper design.

Warranty & Reliability

ACiQ provides 10-year warranty coverage when you register online after purchase. This is competitive for mid-tier equipment and covers compressor, scroll mechanism, and major components. Parts availability through Goodman's supply network is reliable, though this registration requirement means activation during commissioning is critical for claim eligibility.

Specifications

SKUACIQ-30-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU30,000
Heating BTU30,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)120.000000
FeatureSpec
ConfigurationUpflow/Horizontal
Liquid Line3/8"
Suction Line3/4"
Tonnage2.5 Ton
StyleA-Coil
Height38.25"
Width29"
Depth29"
ResourcesGoodman Specifications Goodman Customer Brochure Goodman Installation Instructions Goodman Kit Instructions Goodman Parts Manual Goodman Service Manual Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementMetal
Furnace Efficiency / AFUE80%
Blower MotorHigh Efficiency Multi-Speed
Maximum CFM1200
Burner StagesTwo
Fuel TypeGas
ReplacesGSZ140311
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size30 amps
Min. Breaker Size18.7 amps
Valve TypeSweat
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

What does 14 SEER cooling efficiency actually mean for my electric bill? +
SEER 14 means the system delivers 14 BTU of cooling per watt of electricity consumed, averaged across seasonal conditions. On a typical 2,000-hour cooling season, you'll use roughly 2,140 watts to produce 30,000 BTU, compared to 2,500+ watts with 11 SEER equipment. Expect 15-20% lower cooling costs versus decade-old units.
Can this unit fit in my horizontal attic space that's only 30 inches deep? +
No. The unit is 29 inches wide and 29 inches deep, requiring exactly 29-inch clearance minimum plus 1-2 inches for airflow around the condenser coil. Your 30-inch space leaves only 1 inch on the deepest side, risking restricted airflow and efficiency loss. Verify actual measurements before ordering.
How much better is 14 SEER than the 12 SEER units I'm comparing? +
The efficiency jump from SEER 12 to SEER 14 represents approximately 17% better cooling efficiency. Over a system's 15-year lifespan in a moderate climate, this translates to $800-1,200 in cumulative electric savings, offsetting most or all of the equipment cost premium.
Should I choose this over a 16 SEER variable-speed heat pump? +
A 16 SEER unit runs more efficiently part-load and quieter overall, but costs 25-35% more upfront. If your heating needs dominate and you want gas furnace comfort, this ACiQ's two-stage burner and simpler controls justify the tradeoff. Pure cooling climates favor the higher SEER rating instead.
Does the 10-year warranty cover refrigerant leaks or compressor failure? +
Yes, the 10-year coverage includes compressor failure and sealed-system defects when you register online. Refrigerant recharge labor is typically not covered. Read your warranty paperwork carefully, as registration lapses void coverage for components beyond the compressor.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.