The ACiQ ACIQ-30-EHPD-UPG is a hybrid heat pump and furnace system designed for contractors who understand regional heating needs. It pairs a gas furnace with a heat pump condenser, offering flexibility that straight heat-only equipment cannot match. At $3,109, this 2.5-ton combo sits squarely in the value tier, neither budget-stripped nor premium-priced. Energy Star certification confirms it meets EPA standards, and the AHRI certificate number 7368838 validates its matched-pair performance. This unit targets the practical contractor who prioritizes heating capability over cooling overkill.
The furnace section delivers 60,000 BTU heating capacity with 96% AFUE efficiency, meaning 96 cents of every fuel dollar converts to heat instead of venting away. The two-stage burner modulates between high and low fire, reducing energy waste during mild winter days. The heat pump condenser contributes 30,000 BTU cooling capacity at 14 SEER1, adequate for shoulder seasons and backup cooling. The variable-speed ECM blower motor ramps up or down based on actual load, preventing the energy waste common with fixed-speed fans. These numbers reflect genuine efficiency gains without variable-capacity compressor premiums.
Pros & Cons
Pros
- 96% AFUE furnace efficiency is genuinely excellent, reducing heating costs in cold climates
- 14 SEER1 heat pump rating provides strong cooling performance with R454B refrigerant
- Two-stage burner adapts to heating demand, improving comfort and reducing short-cycling
- Variable-speed ECM blower motor maximizes efficiency across both heating and cooling modes
- PVC exhaust compatibility simplifies installation in homes with older venting systems
- 10-year warranty with online registration covers compressor and parts adequately
Cons
- Single-stage compressor limits part-load efficiency during moderate cooling days
- 74 dB noise level is audible during operation, especially in quiet neighborhoods
- 3-ton cooling capacity oversized if cooling is secondary need, driving unnecessary costs
Who Should Buy
Best For
Northern and Midwest contractors installing systems where heating bills exceed cooling costs, particularly in homes with existing gas infrastructure. Homeowners upgrading from old furnaces who need backup heating and won't pay premium prices for variable-capacity compressors.
Consider Alternatives If
Buyers in hot climates where cooling dominates, or those wanting whisper-quiet outdoor units should explore alternatives.
Installation
The downflow A-coil configuration suits basements and tight attic spaces where horizontal discharge is necessary. Sweat-type valve connections require basic soldering skills, standard for most HVAC techs. PVC exhaust flue compatibility eliminates costly metal ductwork replacements. The 115V single-phase electrical requirement fits standard household panels with an 18.7 to 30-amp breaker. At 120 pounds and 34.5 inches tall, it fits typical utility closets without special structural modifications.
Warranty & Reliability
ACiQ provides 10 years of parts and compressor coverage upon online registration, a straightforward protection level. No deductible mentioned, which is typical for this price range. Coverage lasts the full decade regardless of ownership transfer, beneficial for resale appeal. Registration takes minutes online and unlocks the full term, so skip it at your peril.
Specifications
| SKU | ACIQ-30-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 30,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSZ140311 |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 30 amps |
| Min. Breaker Size | 18.7 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Downflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| AHRI Certificate Number | 7368838 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |