Independent Review · Updated June 2026

2.5 Ton 14.5 SEER 96% AFUE 80,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow

High-efficiency dual-fuel system combining 96% furnace with 14.5 SEER heat pump

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2.5 Ton 14.5 SEER 96% AFUE 80,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow
Current Price
$3309
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ system excels for homeowners in mixed climates who want to maximize heating efficiency with a 96% AFUE furnace while maintaining solid cooling performance at 14.5 SEER. At $3,309, it's an aggressive price point for a combo unit that qualifies for Energy Star rebates.

Review

The ACiQ ACIQ-30-EHPD-UPG represents Goodman's practical approach to hybrid heating and cooling. This 2.5 ton upflow system combines a gas furnace with an air-source heat pump, letting homeowners switch between fuels based on season and cost. At $3,309, it's priced for budget-conscious contractors and DIY installers who understand their local climate demands. The Energy Star certification and available rebates sweeten the economics further.

The furnace delivers serious efficiency at 96% AFUE, meaning minimal heat loss up the flue. The heat pump provides 30,000 BTU cooling capacity at 14.5 SEER, adequate for many mixed-climate homes. Two burner stages and a variable-speed ECM blower let the system run smarter, not just harder. The R454B refrigerant meets current environmental standards. However, the single-stage compressor cannot modulate cooling capacity, so expect some temperature swinging during spring and fall.

Pros & Cons

Pros

  • 96% AFUE furnace efficiency means nearly all fuel converts to heat, reducing gas bills significantly
  • Variable-speed ECM blower motor adapts to actual heating and cooling demand, improving comfort and lowering runtime energy use
  • Two-stage burner operation allows the furnace to run at partial capacity during mild weather, reducing cycling and wear
  • R454B refrigerant reflects current EPA standards and provides better environmental performance than older alternatives
  • 10-year warranty with online registration covers parts and labor, typical for this price tier

Cons

  • Single-stage compressor cannot modulate cooling output, leading to temperature swings in mild weather
  • 74 dB noise level is moderate to loud for outdoor installation in residential areas with close neighbors
  • 3 ton cooling capacity seems undersized relative to 80,000 BTU heating output, suggesting this works best in heating-dominant climates

Who Should Buy

Best For

Contractors and homeowners in northern and mixed climates prioritizing winter heating performance over summer cooling refinement. This system makes sense for properties where natural gas heating runs 6-8 months annually and cooling needs are moderate.

Consider Alternatives If

Anyone in hot climates requiring aggressive cooling or those who value quiet outdoor operation should explore variable-capacity compressors instead.

2.5 Ton 14.5 SEER 96% AFUE 80,000 BTU Goodman Gas
$3309
Buy at HVACDirect →

Installation

This upflow A-coil unit requires 115V single-phase 60Hz power with a 30-amp maximum breaker. Line sets use 3/8 inch liquid and 3/4 inch suction connections with sweat fittings, needing careful brazing during installation. PVC exhaust flue venting simplifies ductwork routing compared to metal pipe. A qualified HVAC installer should handle refrigerant charging and system commissioning.

Warranty & Reliability

ACiQ provides 10 years of parts coverage with online registration, standard for this price point. This covers compressor, heat exchanger, and major components. Labor coverage depends on your contractor's policy. Registration is quick and essential to activate full protection.

Specifications

SKUACIQ-30-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU30,000
Heating BTU80,000
RefrigerantR454B
Electrical115 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)120.000000
FeatureSpec
ReplacesGSZ140311
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size30 amps
Min. Breaker Size18.7 amps
Tonnage3 Ton
Valve TypeSweat
Height34.5"
Width17.5"
Depth28.75"
ResourcesGoodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ConfigurationUpflow/Horizontal
Liquid Line3/8"
Suction Line3/4"
StyleA-Coil
AHRI Certificate Number7368834
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE96%
Blower MotorVariable Speed - ECM
Maximum CFM1200
Burner StagesTwo
Fuel TypePropane, Natural Gas
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

Why is the cooling tonnage 3 tons when the product name says 2.5 ton? +
The SKU reflects the heat pump's actual 30,000 BTU cooling output, which equals 2.5 tons. Industry specs sometimes use the higher nominal rating. Verify the 30,000 BTU figure matches your home's cooling load calculations to avoid undersizing.
Can this system work in my climate if winters are mild but summers are hot? +
Not ideally. The single-stage compressor delivers full cooling capacity immediately, creating overshoot and temperature swings. You'd also underutilize the 96% furnace in warm winters. A variable-capacity heat pump would suit hot climates better.
What makes the 96% AFUE furnace valuable compared to standard units? +
At 96% AFUE, only 4% of gas energy escapes as flue loss, versus 15-20% with older furnaces. Across a 100,000 BTU heating season, that's roughly $300-500 in recovered heat annually, paying back efficiency upgrades faster.
How does the variable-speed blower save money versus fixed-speed? +
Variable ECM motors ramp down during mild heating, reducing electricity draw from continuous full-speed rotation. This typically saves 20-30% on blower energy use annually while improving temperature consistency and reducing noise.
Is the 10-year warranty comprehensive if my installer doesn't register the unit? +
No. Registration is mandatory for full coverage. Without it, coverage may default to 5 years or less. Complete registration immediately after installation to protect your investment.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.