Review
The ACiQ ACIQ-24-EHPD-UPG is a workhorse dual-fuel system built on the proven Goodman platform. It pairs an 80,000 BTU gas furnace with a 24,000 BTU (2 ton nominal) heat pump in a compact downflow A-coil configuration. This combination targets mid-range contractors and homeowners who want solid efficiency without paying for advanced modulation technology. The system carries Energy Star certification and uses R454B refrigerant, meeting current environmental standards.
Performance numbers tell the real story here. The gas furnace delivers 96% AFUE with two-stage burner capability, meaning it runs at reduced capacity most of the year and only fires the second stage during cold snaps. The heat pump achieves 14 SEER1 cooling efficiency with a single-stage scroll compressor, keeping things simple and reliable. The variable-speed ECM blower handles up to 1,200 CFM and operates at 70 dBA, which is reasonable for single-stage equipment. Electrical draw maxes out at 25 amps on a standard 115V circuit.
Pros & Cons
Pros
- 96% AFUE gas furnace delivers exceptional heating efficiency and lower fuel bills
- 14 SEER rating meets Energy Star standards with R454B low-GWP refrigerant
- Variable-speed ECM blower motor provides quiet operation at 70 dBA and flexible comfort control
- Two-stage burner enables modulation for consistent temperatures and reduced cycling
- 10-year warranty with online registration covers both heat pump and furnace components
- PVC flue compatibility simplifies venting in modern homes without masonry chimneys
Cons
- Single-stage compressor limits capacity modulation compared to two-stage competitors
- 3 ton cooling capacity exceeds the 2 ton nameplate, creating potential oversizing issues in smaller spaces
- 70 dBA noise level runs slightly higher than premium single-stage units, noticeable during compressor operation
Who Should Buy
Best For
Contractors installing systems in homes with natural gas or propane service will appreciate the straightforward two-stage design and reliable scroll compressor. Homeowners in moderate climates using both heating and cooling will see solid returns from the 96% AFUE and 14 SEER efficiency ratings.
Consider Alternatives If
Skip this if you need variable-capacity cooling for precise dehumidification or prefer quieter operation below 65 dBA.
Installation
This downflow unit requires right-side flue venting through PVC or plastic ducting, standard in newer construction. Refrigerant lines use 3/8 inch liquid and 3/4 inch suction connections with sweat fittings, so installers need soldering capability. The 50-foot suction line with 3/4 inch insulation comes included. Dimensions of 34.5 by 17.5 by 28.75 inches fit most attic or basement installations. Expect 4-6 hours for a straightforward changeover replacement.
Warranty & Reliability
ACiQ backs this system with a 10-year parts warranty upon online registration, covering both the heat pump and furnace components equally. Registration is quick and protects you against manufacturing defects. This matches industry standard for mid-tier equipment, though premium brands sometimes offer extended coverage. Proof of professional installation is typically required for claims.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 70 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSZ140251 |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 17.1 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Downflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Flue Location | Right |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.