Independent Review · Updated June 2026

2 Ton 14 SEER Goodman Heat Pump Air Conditioner System

Solid 14 SEER heat pump with modern refrigerant and rebate eligibility

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2 Ton 14 SEER Goodman Heat Pump Air Conditioner System
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ 2 ton unit is ideal for contractors replacing older Goodman models or homeowners in moderate climates wanting efficient heating and cooling in one system. The 14 SEER rating, R454B refrigerant compliance, and available rebates make it a smart retrofit choice for those upgrading from single-stage equipment.

Review

The ACiQ 2 ton heat pump (SKU ACIQ-24-EHPD-UPG) represents a direct upgrade path for contractors and homeowners maintaining Goodman equipment. As a replacement for the discontinued GSZ140251, this unit preserves installation familiarity while introducing modern R454B refrigerant compliance. The 14 SEER efficiency rating positions it as a practical middle ground, outperforming baseline systems while remaining competitively priced against premium variable-capacity models.

Performance specs tell a practical story. Cooling output reaches 24,000 BTU with heating capability of 34,100 BTU, covering most moderate climate needs. The scroll compressor operates on 208/230/240 volts single phase, requiring a 57 to 60 amp breaker. At 70 dB, expect audible operation during peak cooling. Multi-speed EEM blower motor pushes 1,050 CFM maximum, adequate for 2 ton sizing in properly sealed homes. Energy Star certification confirms the 14 SEER rating meets federal efficiency thresholds without rebate hassles.

Pros & Cons

Pros

  • 14 SEER efficiency rating exceeds baseline requirements and qualifies for Energy Star certification
  • R454B refrigerant meets modern environmental standards without costly system redesigns
  • Dual-function design delivers 24,000 BTU cooling and 34,100 BTU heating from one outdoor unit
  • Scroll compressor is proven technology with lower field failure rates than rotary designs
  • 10 year warranty with online registration provides solid long-term protection
  • Optional electric backup heat up to 10 kilowatts handles extreme cold without fossil fuels

Cons

  • Single-stage compressor means less efficient part-load operation compared to variable-capacity competitors
  • 70 dB noise level is audible and may concern noise-sensitive residential locations
  • 2 ton capacity limits applications to smaller homes or rooms, ruling out whole-house retrofit for larger properties

Who Should Buy

Best For

Contractors replacing GSZ140251 units will appreciate the direct compatibility and familiar Goodman service network. Homeowners in mild to moderate climates with homes under 1,200 square feet will see meaningful savings on heating and cooling bills with the 14 SEER rating.

Consider Alternatives If

Buyers in extremely cold climates should look at higher tonnage models with auxiliary heating, and noise-sensitive properties near bedrooms need units rated below 65 dB.

2 Ton 14 SEER Goodman Heat Pump Air Conditioner Sy
$0
Buy at HVACDirect →

Installation

Sweat-type connections (3/8 inch liquid line, 3/4 inch suction line) require trained technicians comfortable with brazing. The 45 inch height, 17.5 inch width, and 21 inch depth fit standard outdoor pads. Pre-charged 50 foot linesets simplify job site logistics. Electrical rough-in demands single-phase wiring with appropriate breaker sizing, a straightforward requirement for most residential installations.

Warranty & Reliability

Ten years of parts coverage kicks in after online registration, protecting against defects in compressor, coil, and controls. This covers most field failures contractors encounter. Owner must maintain professional service records and proper refrigerant charge for validity. Registration is mandatory, not automatic, so document the process at commissioning.

Specifications

SKUACIQ-24-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU24,000
Heating BTU34,100
RefrigerantR454B
Electrical208 / 230 / 240 Volts / 1 Phase
Warranty10 Years with Online Registration
Decibel Level (dBA)70
Weight (in lbs)120.000000
FeatureSpec
ReplacesGSZ140251
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size60 amps
Min. Breaker Size57 amps
Tonnage2 Ton
Valve TypeSweat
Height45"
Width17.5"
Depth21"
ResourcesGoodman Installation Manual Goodman Specifications Goodman Parts Manual Goodman Service Manual Goodman Kit Installation Manual You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
Blower MotorMulti Speed - EEM
Maximum CFM1,050
Electric Backup Heat Capabilities (Optional)5 Kilowatts, 8 Kilowatts, 10 Kilowatts
Filter Size16" x 20"
Liquid Line3/8"
Suction Line3/4"
Fuel TypeElectric
Suction Line Insulation Thickness3/4"
Length50 feet
Electric Heat10 Kilowatts
PhaseSingle Phase

Frequently Asked Questions

Will this unit work as a direct replacement for my Goodman GSZ140251? +
Yes. The ACIQ-24-EHPD-UPG is engineered as a direct replacement. Suction and liquid valve sizes match, electrical requirements align, and mounting footprints are compatible. Your existing lineset and indoor coil should work without modifications if properly maintained.
What breaker size do I need for this heat pump? +
You need a minimum 57 amp and maximum 60 amp breaker. Use 60 amps for safety margin. Single-phase 208/230/240 volt service handles the load. Have a licensed electrician verify your panel capacity before installation to avoid nuisance trips.
Is 14 SEER good enough compared to newer 16 SEER units? +
14 SEER saves roughly 12 percent more energy than baseline 10 SEER systems. Upgrade to 16 SEER costs 15 to 20 percent more but saves only 3 to 4 percent additional energy annually. For moderate climates, 14 SEER offers solid ROI without premium pricing.
Can I add electric backup heat if winters are cold? +
Yes. Optional electric heat strips are available in 5, 8, or 10 kilowatt configurations. The 10 kilowatt option avoids most resistance heating during defrost cycles. Confirm your electrical service can handle the additional load before ordering strips.
What happens if I don't register the warranty online? +
Warranty becomes void without registration. Complete the online process immediately after commissioning using the serial number. Keep confirmation documentation with the unit nameplate photo for future service claims.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.