Independent Review · Updated June 2026

2 Ton 15 SEER Goodman Heat Pump Variable Speed Air Conditioner System - Horizontal

Budget-friendly 2-ton heat pump with variable speed efficiency and solid SEER ratings

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2 Ton 15 SEER Goodman Heat Pump Variable Speed Air Conditioner System - Horizontal
Current Price
$766
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ unit delivers strong value for contractors and homeowners looking for an affordable 2-ton heat pump with respectable 14 SEER1 efficiency. The variable-speed ECM blower and Energy Star certification make it practical for moderate climates where supplemental heat needs are moderate.

Review

The ACiQ 2-ton heat pump hits a sweet spot in the budget HVAC market. Built on Goodman's proven platform and priced at just $766, this horizontal A-coil unit delivers reliable heating and cooling without premium pricing. It's designed for residential applications where contractors need solid performance without the cost premium of high-efficiency tiers. The Energy Star certification signals real efficiency gains over older equipment, making it practical for homeowners upgrading aging systems.

Performance specs show this unit handles 24,000 BTU cooling and heating output with a 14 SEER1 rating and variable-speed ECM blower motor. The scroll compressor and 1,200 CFM maximum airflow provide adequate capacity for mid-sized homes. Operating on standard 208/230V single-phase power with a 17.1 to 25 amp breaker range keeps installation straightforward. The R454B refrigerant reflects current environmental standards, though you'll note this is SEER1 rather than the newer SEER2 standard some competitors already publish.

Pros & Cons

Pros

  • Variable-speed ECM blower reduces runtime and energy waste compared to single-stage motors
  • 14 SEER1 rating with Energy Star certification provides solid long-term efficiency gains
  • 24,000 BTU heating and cooling capacity handles most residential 2-ton applications effectively
  • Flexible electric backup heat options from 3 kW to 15 kW accommodate various installation scenarios
  • Affordable $766 price point makes it competitive against higher-tier Goodman and Carrier units
  • 10-year warranty with online registration provides reasonable coverage for the price tier

Cons

  • 14 SEER1 is respectable but trails newer 15+ SEER2 models from competitors by 1-2 efficiency points
  • Single-stage compressor limits part-load efficiency compared to variable-capacity alternatives
  • 70 dB noise level is moderately loud for residential applications, especially during peak cooling
  • Documentation requires Adobe Reader, limiting accessibility for some users

Who Should Buy

Best For

Budget-conscious contractors installing systems in moderate climates where heating demands stay reasonable, and homeowners replacing older units who prioritize upfront savings over premium efficiency. This unit works best in areas with mild winters where the optional backup heat won't run constantly.

Consider Alternatives If

Anyone in cold climates requiring frequent electric supplemental heat, or buyers seeking top-tier SEER2 ratings and ultra-quiet operation should explore 15+ SEER2 models from Trane or Lennox.

2 Ton 15 SEER Goodman Heat Pump Variable Speed Air
$766
Buy at HVACDirect →

Installation

Installation is straightforward for experienced technicians. The unit requires 208/230V single-phase 60 Hz power and fits standard 17.1 to 25 amp breaker sizing. Horizontal A-coil configuration with 3/8 inch liquid and 3/4 inch suction connections matches common lineset specifications. The 120-pound weight is manageable for two technicians. Includes 50 feet of suction line insulation at 3/4 inch thickness, reducing field fabrication needs.

Warranty & Reliability

ACiQ provides 10 years of coverage when you register online, which is competitive for budget equipment. The registration requirement is straightforward but mandatory to activate the full term. This covers manufacturing defects but excludes wear items and improper installation. For a $766 unit, ten years of protection represents solid value, though premium brands sometimes extend to 12 years.

Specifications

SKUACIQ-24-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU24,000
Heating BTU24,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)70
Weight (in lbs)120.000000
FeatureSpec
Blower MotorVariable Speed - ECM
Maximum CFM1,200
Electric Backup Heat Capabilities (Optional)3 Kilowatts, 5 Kilowatts, 6 Kilowatts, 8 Kilowatts, 10 Kilowatts, 15 Kilowatts
Max Breaker Size25 amps
Tonnage3 Ton
Height21.125"
Width17.5"
Depth26"
ResourcesCHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ReplacesGSZ140251
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Min. Breaker Size17.1 amps
Valve TypeSweat
ConfigurationHorizontal
Liquid Line3/8"
Suction Line3/4"
StyleA-Coil
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

How does the 14 SEER1 rating compare to newer systems? +
14 SEER1 is solid mid-range efficiency and beats most pre-2015 equipment. However, newer 15+ SEER2 models from competitors deliver approximately 10 to 15 percent additional efficiency gains. The trade-off is typically $400 to $800 higher upfront cost versus potential $100 to $200 annual operating savings.
Can I install this in an attic or crawlspace? +
Yes. The horizontal A-coil configuration and 21.125 inch height work in tight spaces. Verify your opening clears 26 inches depth and 17.5 inches width. Ensure adequate return and supply ductwork clearance. Attic installations should have proper ventilation to prevent heat buildup around the coil.
What does the variable-speed blower actually save? +
The ECM motor ramps to demand rather than running full-speed constantly, reducing electricity draw by 15 to 25 percent during light-load conditions. You'll notice quieter operation and more consistent temperatures. In moderate climates, this translates to real savings that offset the slightly higher cost versus single-speed alternatives.
Should I choose 3 kW or 15 kW backup heat? +
Backup heat sizing depends on your winter climate. Mild climates like zones 4b to 5a typically use 3 to 5 kW. Cold climates with frequent below-freezing temperatures need 8 to 15 kW to prevent auxiliary heat overuse. Work with your installer to right-size based on your specific location and demand patterns.
Does online registration actually matter for warranty? +
Yes. Registration is required to activate the full 10-year coverage. Without it, you may only receive a limited 1-year warranty. Registration takes five minutes online and protects your investment, so don't skip this step after installation.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.