Review
The Goodman 2 Ton 16 SEER heat pump represents the practical middle ground in the residential HVAC market. Despite the spec sheet listing "3 Ton" tonnage, this is actually a 2-ton unit with 24,000 BTU cooling and heating capacity, making it suitable for small to medium homes or supplemental zoning. Online Supply positions this as a rebate-eligible system, and the ENERGY STAR certification backing confirms real-world efficiency gains. For contractors, the upflow/downflow A-coil configuration offers genuine installation flexibility without extensive redesigns.
Performance metrics show solid engineering for the price point. The 16 SEER rating translates to approximately 30-35% better efficiency than 13 SEER baseline models, reducing summer cooling costs substantially. Two-stage compressor operation means the unit runs at partial capacity most of the time, cutting runtime noise and extending equipment life. The variable-speed ECM blower (maximum 1,600 CFM) automatically adjusts airflow, preventing the short-cycling and humidity problems common with single-speed units. At 208/230V single-phase with 15.8 to 25 amp breaker requirements, it integrates into standard residential electrical service without expensive upgrades.
Pros & Cons
Pros
- 16 SEER efficiency rating qualifies for ENERGY STAR and many utility rebates, reducing operating costs
- Variable-speed ECM blower motor adjusts CFM up to 1,600 for better comfort and lower energy waste
- Two-stage condenser allows modulated cooling, improving dehumidification and quieter operation at part load
- Multiple electric backup heat options from 3 to 15 kilowatts accommodate various climate needs
- Compact 22-inch cube footprint fits tight mechanical rooms and attics in retrofit applications
- Scroll compressor design offers proven reliability with lower maintenance requirements
Cons
- 72 dBA noise level is moderate, not ideal for homes with noise-sensitive occupants or close neighbors
- R410A or R22 refrigerant compatibility creates service complexity, as technicians must confirm which refrigerant the paired outdoor unit uses
- Missing SEER2 rating on spec sheet leaves efficiency comparison unclear against newer industry standards
- No mention of smart thermostat integration or connectivity features found in competing models
Who Should Buy
Best For
Contractors installing in homes across moderate climates where heating and cooling demands are roughly equal. Homeowners replacing older systems in upflow or downflow configurations who want reliable mid-tier efficiency without premium pricing.
Consider Alternatives If
Anyone in extreme climates needing maximum heating capacity, or those prioritizing whisper-quiet operation should explore higher-end variable-speed models or alternative brands.
Installation
Installation complexity is moderate. The 3/8-inch liquid line and 3/4-inch suction line with factory insulation require careful handling during coil placement. Sweat valve connections demand soldering expertise, so inexperienced DIYers should hire certified technicians. The compact 22-inch dimensions allow placement in tight spaces, though weight (22 lbs) is manageable for one person. Paired outdoor condenser sizing is critical, as refrigerant mismatch (R410A versus R22) between indoor and outdoor units causes system failure.
Warranty & Reliability
Goodman offers a 10-year parts warranty conditional on online registration, a standard industry practice. This coverage typically includes compressor, refrigerant leaks, and major components, but excludes labor and routine maintenance. Registration must occur within 30 days of installation to activate full coverage. No extended warranty options appear listed, so buyers seeking longer protection should discuss third-party plans with their contractor at purchase.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 24,000 |
| Heating BTU | 24,000 |
| Refrigerant | R410A or R22 |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 72 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1,600 |
| Electric Backup Heat Capabilities (Optional) | 3 Kilowatts, 5 Kilowatts, 6 Kilowatts, 8 Kilowatts, 10 Kilowatts, 15 Kilowatts |
| Max Breaker Size | 25 amps |
| Tonnage | 3 Ton |
| Height | 22" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Product Features | Rebate Available, Two Stage Condenser |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Two Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Min. Breaker Size | 15.8 amps |
| Valve Type | Sweat |
| Configuration | Upflow / Downflow |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.