Independent Review · Updated June 2026

3 Ton 14 SEER 80% AFUE 100,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow

Solid mid-tier heat pump system delivering 14 SEER cooling with dependable gas backup.

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
3 Ton 14 SEER 80% AFUE 100,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ system suits contractors and homeowners in moderate climates needing dual heating capability without premium pricing. The 14 SEER rating and 80% AFUE furnace strike a practical balance between efficiency gains and installation simplicity in upflow applications.

Review

The ACiQ 3-ton 14 SEER heat pump with 80% AFUE gas furnace combines accessible efficiency with practical dual-fuel heating. This upflow A-coil configuration addresses standard residential comfort needs in moderate climates without premium complexity. Positioned between budget equipment and high-efficiency systems, it attracts contractors managing cost-conscious replacements and homeowners upgrading from aging single-stage units.

Cooling capacity reaches 36,000 BTU through a scroll compressor operating at 74 dB, while the two-stage gas furnace delivers 100,000 BTU heating output. The high-efficiency multi-speed blower reaches 2,000 CFM maximum airflow, providing responsive temperature control. R410A refrigerant with 3/8-inch liquid and 7/8-inch suction lines follow industry standards, making service straightforward for most technicians.

Pros & Cons

Pros

  • 14 SEER cooling efficiency matches modern efficiency standards for most climate zones without extreme cost
  • Dual-fuel design with 100,000 BTU gas furnace provides reliable backup heating during extreme cold
  • 80% AFUE gas furnace is straightforward to maintain, with two-stage burner for better modulation
  • High-efficiency multi-speed blower motor maximizes 2,000 CFM output while reducing runtime energy consumption
  • 10-year warranty with online registration covers parts and labor in most regions
  • Scroll compressor delivers proven reliability with minimal maintenance in residential applications

Cons

  • 14 SEER is competent but not exceptional, with higher-tier systems reaching 16+ SEER for similar cost
  • 80% AFUE furnace lags behind 95%+ AFUE high-efficiency models, increasing gas heating costs over time
  • Single-stage condenser limits adaptive capacity modulation compared to variable-speed alternatives
  • 74 dB noise level is acceptable but audible, particularly during peak cooling demand

Who Should Buy

Best For

Contractors installing systems in areas with moderate heating and cooling seasons who value straightforward service and quick replacement cycles. Homeowners seeking reliable dual-fuel comfort without investing in premium variable-capacity equipment.

Consider Alternatives If

Buyers in very cold climates prioritizing heating efficiency, or those seeking maximum cooling performance in hot, humid regions should explore 16+ SEER and 95%+ AFUE alternatives.

3 Ton 14 SEER 80% AFUE 100,000 BTU Goodman Gas Fur
$0
Buy at HVACDirect →

Installation

Installation requires 120V single-phase 60Hz power with breaker sizing between 22.4 and 30 amps, standard for most homes. Metal exhaust flue, sweat valve connections, and 50-foot suction line with 3/4-inch insulation are specified. Upflow configuration fits attic or basement placement, though proper ductwork design and refrigerant line sizing remain critical for performance.

Warranty & Reliability

Ten-year parts coverage activates through online registration, a common requirement protecting manufacturer costs. Most regional HVAC contractors honor this warranty during service calls. Coverage typically excludes damage from improper installation, neglected maintenance, or non-approved repairs, so retain documentation and service records.

Specifications

SKUACIQ-36-HPC-UPG
Brand/ManufacturerACiQ
Cooling BTU36,000
Heating BTU100,000
RefrigerantR410A
Electrical120 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)120.000000
FeatureSpec
ReplacesGSZ140371
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size30 amps
Min. Breaker Size22.4 amps
Tonnage5 Ton
Valve TypeSweat
Height34.5"
Width21"
Depth28.75"
ResourcesGoodman Brochure Goodman Installation Manual Goodman Specifications Goodman Parts Manual Goodman User Information Goodman Service Manual Goodman Technical Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ConfigurationUpflow/Horizontal
Liquid Line3/8"
Suction Line7/8"
StyleA-Coil
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementMetal
Furnace Efficiency / AFUE80%
Blower MotorHigh Efficiency Multi-Speed
Maximum CFM2000
Burner StagesTwo
Fuel TypeGas
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

How does 14 SEER compare to other mid-range heat pumps? +
14 SEER meets ENERGY STAR standards and suits moderate climates effectively. Higher-efficiency 16-18 SEER units reduce electricity use roughly 12-28% but cost significantly more upfront. This model balances efficiency gains against affordability for contractors and homeowners avoiding premium pricing.
Can this system replace my old 3-ton furnace and AC? +
Yes, the 3-ton capacity matches standard residential applications. However, verify your existing ductwork, electrical panel capacity, and whether upflow/horizontal configuration fits your space. If upgrading to 5-ton capacity, consult a contractor about airflow requirements.
What heating efficiency should I expect from the gas furnace? +
80% AFUE means 80 cents of heating energy reaches your home per dollar spent on gas, with 20% lost through exhaust. High-efficiency models reach 95% AFUE but cost more. For moderate winter climates, 80% AFUE delivers reasonable performance without extensive retrofitting.
Is this system suitable for very cold climates? +
It functions in cold climates but isn't optimized for them. The two-stage gas furnace becomes primary in sustained freezing temperatures, reducing heat pump efficiency benefits. Regions with frequent sub-zero stretches should consider 95%+ AFUE furnaces or backup electric strips.
What does the 10-year warranty actually cover? +
Parts and labor on manufacturing defects when registered online. Most contractors honor this through their service agreements. Verify regional policy with your installer, as coverage scope varies slightly by distributor and location.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.