Review
The ACiQ 3-ton dual-fuel system bridges an important market gap for homeowners who want efficient summer cooling without abandoning proven gas heating. At 14 SEER and 100,000 BTU capacity, this unit represents a practical middle ground between basic single-fuel systems and full-conversion heat pumps. The Goodman backing and Energy Star certification signal solid engineering, though the 80% AFUE rating shows this is not a premium efficiency product.
Performance specs reveal capable but not cutting-edge equipment. The 36,000 BTU cooling output with 14 SEER efficiency handles most residential loads efficiently, while the two-stage 100,000 BTU furnace prevents overshooting in mild weather. A variable-speed blower motor managing up to 2,000 CFM improves comfort compared to single-speed alternatives. The scroll compressor and R410A refrigerant are industry standard, and the 120V electrical requirement works with standard residential panels at 22.4 to 30 amps.
Pros & Cons
Pros
- 14 SEER cooling efficiency exceeds minimum standards, reducing summer energy costs measurably
- Dual-fuel design combines heat pump efficiency with gas furnace reliability for year-round comfort
- 100,000 BTU heating capacity with two-stage burners provides precise temperature control
- Variable-speed blower motor adjusts airflow up to 2,000 CFM for better humidity management
- 10-year warranty with online registration covers parts and provides peace of mind
Cons
- 80% AFUE furnace is dated compared to 90%+ high-efficiency models now standard
- Single-stage compressor cannot modulate cooling capacity, leading to some short-cycling in mild weather
- 74 dB noise level runs louder than quieter premium units, noticeable from nearby rooms
- Requires metal exhaust flue and proper venting setup, complicating some retrofit installations
Who Should Buy
Best For
Homeowners in regions with moderate winters and hot summers who want efficient cooling without investing in full heat pump systems. Also suited for those replacing older dual-fuel equipment who need gas backup reliability alongside modern cooling efficiency.
Consider Alternatives If
Buyers in very cold climates should look at higher-efficiency furnaces, and those seeking premium quiet operation should compare units with lower decibel ratings.
Installation
Installation demands proper refrigerant line sizing with 3/8-inch liquid and 7/8-inch suction lines, plus 3/4-inch insulation thickness to prevent efficiency loss. The upflow A-coil configuration suits attic or basement placement. Metal exhaust venting is mandatory for the furnace. Most contractors complete installation in one day, though ductwork modifications may add cost in older homes with undersized systems.
Warranty & Reliability
ACiQ provides 10 years coverage on parts with online registration, protecting against compressor failure and major component defects. This standard warranty does not cover refrigerant, labor, or damage from improper installation. Registration is straightforward and essential, as unregistered units typically receive only 5-year coverage.
Specifications
| SKU | ACIQ-36-HPC-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 36,000 |
| Heating BTU | 100,000 |
| Refrigerant | R410A |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSZ140371 |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 30 amps |
| Min. Breaker Size | 22.4 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 21" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.