Independent Review · Updated June 2026

3 Ton 14 SEER 80% AFUE 100,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow

Solid 14 SEER heat pump with 80% gas furnace backup for mixed climates

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
3 Ton 14 SEER 80% AFUE 100,000 BTU Goodman Gas Furnace and Heat Pump System - Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ unit is ideal for homeowners in moderate climates who want efficient cooling (14 SEER) paired with gas heating backup. The 100,000 BTU furnace with 80% AFUE and two-stage burner delivers solid winter performance without breaking the bank on a full heat pump system.

Review

The ACiQ 3-ton dual-fuel system bridges an important market gap for homeowners who want efficient summer cooling without abandoning proven gas heating. At 14 SEER and 100,000 BTU capacity, this unit represents a practical middle ground between basic single-fuel systems and full-conversion heat pumps. The Goodman backing and Energy Star certification signal solid engineering, though the 80% AFUE rating shows this is not a premium efficiency product.

Performance specs reveal capable but not cutting-edge equipment. The 36,000 BTU cooling output with 14 SEER efficiency handles most residential loads efficiently, while the two-stage 100,000 BTU furnace prevents overshooting in mild weather. A variable-speed blower motor managing up to 2,000 CFM improves comfort compared to single-speed alternatives. The scroll compressor and R410A refrigerant are industry standard, and the 120V electrical requirement works with standard residential panels at 22.4 to 30 amps.

Pros & Cons

Pros

  • 14 SEER cooling efficiency exceeds minimum standards, reducing summer energy costs measurably
  • Dual-fuel design combines heat pump efficiency with gas furnace reliability for year-round comfort
  • 100,000 BTU heating capacity with two-stage burners provides precise temperature control
  • Variable-speed blower motor adjusts airflow up to 2,000 CFM for better humidity management
  • 10-year warranty with online registration covers parts and provides peace of mind

Cons

  • 80% AFUE furnace is dated compared to 90%+ high-efficiency models now standard
  • Single-stage compressor cannot modulate cooling capacity, leading to some short-cycling in mild weather
  • 74 dB noise level runs louder than quieter premium units, noticeable from nearby rooms
  • Requires metal exhaust flue and proper venting setup, complicating some retrofit installations

Who Should Buy

Best For

Homeowners in regions with moderate winters and hot summers who want efficient cooling without investing in full heat pump systems. Also suited for those replacing older dual-fuel equipment who need gas backup reliability alongside modern cooling efficiency.

Consider Alternatives If

Buyers in very cold climates should look at higher-efficiency furnaces, and those seeking premium quiet operation should compare units with lower decibel ratings.

3 Ton 14 SEER 80% AFUE 100,000 BTU Goodman Gas Fur
$0
Buy at HVACDirect →

Installation

Installation demands proper refrigerant line sizing with 3/8-inch liquid and 7/8-inch suction lines, plus 3/4-inch insulation thickness to prevent efficiency loss. The upflow A-coil configuration suits attic or basement placement. Metal exhaust venting is mandatory for the furnace. Most contractors complete installation in one day, though ductwork modifications may add cost in older homes with undersized systems.

Warranty & Reliability

ACiQ provides 10 years coverage on parts with online registration, protecting against compressor failure and major component defects. This standard warranty does not cover refrigerant, labor, or damage from improper installation. Registration is straightforward and essential, as unregistered units typically receive only 5-year coverage.

Specifications

SKUACIQ-36-HPC-UPG
Brand/ManufacturerACiQ
Cooling BTU36,000
Heating BTU100,000
RefrigerantR410A
Electrical120 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)120.000000
FeatureSpec
ReplacesGSZ140371
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size30 amps
Min. Breaker Size22.4 amps
Tonnage5 Ton
Valve TypeSweat
Height34.5"
Width21"
Depth28.75"
ResourcesGoodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ConfigurationUpflow/Horizontal
Liquid Line3/8"
Suction Line7/8"
StyleA-Coil
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementMetal
Furnace Efficiency / AFUE80%
Blower MotorVariable Speed
Maximum CFM2000
Burner StagesTwo
Fuel TypePropane, Natural Gas
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

Will this system replace my old Goodman furnace and air conditioner separately? +
Yes, it replaces the GSZ140371 model. The integrated design combines both functions in one compact footprint, eliminating redundant equipment. Installation requires connecting existing ductwork, electrical lines, and refrigerant lines from your coil. Most contractors charge $500 to $1,200 for labor depending on your setup's complexity.
What electrical panel upgrades are needed for installation? +
None if your panel has a 30-amp breaker available. The unit requires 22.4 to 30 amps at 120V single phase 60 Hz. Standard residential panels can handle this. If your panel lacks space, adding a breaker costs $150 to $300 professionally installed.
How does 14 SEER compare to newer units, and what will my cooling bills look like? +
14 SEER is above minimum standards but trails newer 16-18 SEER units. On a 3-ton system running 1,500 cooling hours yearly, expect $25 to $40 monthly savings versus 10 SEER equipment. Exact savings depend on local electricity rates, typically $300 to $480 annually in moderate climates.
Should I choose this over a full heat pump system without gas backup? +
Choose gas backup if winters regularly drop below 35 degrees or you live in areas with frequent power outages. Full heat pumps excel in mild climates. This dual-fuel unit costs more upfront but avoids auxiliary electric heating strips that spike bills during cold snaps in transitional climates.
Is the 10-year warranty actually useful, or does it exclude most failures? +
It covers legitimate compressor and component failures well. The main limitations are refrigerant charge, installation labor, and damage from poor maintenance or freezing. Register promptly online to activate coverage, otherwise you get only 5 years.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.