Review
The ACiQ 5-ton combo system branded under Goodman represents the practical middle ground in residential HVAC. With 14 SEER cooling efficiency and 80% AFUE heating, this upflow configuration balances performance against installation cost. Contractors frequently specify this unit for replacement jobs where homes need measurable efficiency improvements without premium pricing. The R454B refrigerant aligns with current EPA standards, avoiding costly retrofits. At 120 pounds and 30 inches tall, it fits standard basement and closet installations common in suburban American homes.
Performance specs reveal a competent, conventional design. The cooling side delivers 57,000 BTU with a single-stage scroll compressor and 14 SEER rating across 2,000 CFM maximum airflow. The heating side generates 58,000 BTU through a two-stage gas burner at 80% AFUE, using standard metal exhaust flue venting. Multi-speed blower operation helps modulate comfort, though the single-stage condenser doesn't vary capacity on mild days. Electrical draw runs 208/230V single phase with 34.6 to 60 amp breaker sizing, typical for five-ton applications. Real-world users report quiet operation, though measured at 77 dB from the unit itself.
Pros & Cons
Pros
- 14 SEER delivers solid efficiency without premium pricing, matching mid-range market expectations
- Two-stage burner and multi-speed blower reduce short-cycling and improve comfort consistency
- 80% AFUE furnace provides adequate heating with 58,000 BTU output in two modulation stages
- R454B refrigerant meets current environmental regulations without costly retrofit requirements
- Compact 30-inch height and A-coil configuration fits tight basements and crawlspaces
- 10-year warranty with online registration provides reasonable homeowner confidence
Cons
- 14 SEER is respectable but trails newer 16-18 SEER systems by 15-30% in cooling efficiency
- 80% AFUE furnace requires annual maintenance and isn't eligible for high-efficiency rebates
- Single-stage condenser lacks variable capacity, potentially wasting energy during mild days
- 77 dB noise level is audible from nearby rooms, higher than quieter two-stage units
- Not Energy Star certified, limiting appeal to environmentally conscious buyers seeking recognition
Who Should Buy
Best For
Contractors replacing older 10-13 SEER systems for budget-conscious homeowners in mixed climates who want measurable efficiency gains without six-figure system costs. Residential customers comfortable with mid-range equipment and looking for reliable operation over 15-20 years appreciate this system's straightforward engineering.
Consider Alternatives If
Skip this if you need true high-efficiency performance, live in consistently hot climates where 18+ SEER makes financial sense, or prioritize ultra-quiet operation below 70 dB.
Installation
Installation follows conventional split-system procedures. Requires metal exhaust flue for the furnace, 3/8-inch liquid line and 1 1/8-inch suction line with 1/2-inch insulation thickness up to 50 feet. Sweat valve connections demand basic refrigeration skills. The compact footprint suits upflow basement placement and horizontal attic mounting. Multi-speed blower integrates easily with most ductwork. Most contractors complete installation in one to two days with standard tools.
Warranty & Reliability
Goodman offers a 10-year parts warranty when customers register online within 30 days of installation. Coverage applies to compressor, coil, and furnace components. Registration is straightforward but mandatory, as default coverage reverts to shorter terms. This aligns with industry standards for mid-tier equipment and provides meaningful protection during critical early years when failures most commonly occur.
Specifications
| SKU | ACIQ-60-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 57,000 |
| Heating BTU | 58,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 77 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Multi-Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Gas |
| Height | 30" |
| Width | 24.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Replaces | GSZ140611 |
| Energy Star | No |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 60 amps |
| Min. Breaker Size | 34.6 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.