Independent Review · Updated June 2026

Goodman 5 Ton 14 SEER Heat Pump Split System - R410A Single Stage - Multi-Positional

Solid mid-tier heat pump with strong heating output and straightforward installation.

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
Goodman 5 Ton 14 SEER Heat Pump Split System - R410A Single Stage - Multi-Positional
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
Best for contractors and homeowners upgrading older systems in moderate climates who prioritize heating performance and want reliable single-stage operation. The 68,200 BTU heating capacity and R454B refrigerant make this particularly suited for homes needing dependable year-round comfort without premium pricing.

Review

The Goodman 5 Ton 14 SEER heat pump split system represents the practical middle ground in residential HVAC equipment. This ACiQ-manufactured unit delivers capable heating and cooling without premium pricing, making it attractive to cost-conscious contractors and homeowners alike. The single-stage scroll compressor design prioritizes reliability over complexity, and the R454B refrigerant ensures compatibility with current EPA standards for years to come.

Performance numbers tell a straightforward story. Cooling capacity reaches 57,000 BTU, while heating output hits an impressive 68,200 BTU, making this unit particularly valuable for properties with genuine heating needs. The 14 SEER rating translates to moderate energy efficiency, not exceptional but respectable for this equipment class. Airflow capacity of 2,265 CFM through the multi-speed EEM blower provides flexibility for ductwork configurations. The 77 dBA noise output is acceptable for most installations but worth noting for noise-sensitive properties.

Pros & Cons

Pros

  • Strong heating output of 68,200 BTU, outperforming many competitors in its tonnage class
  • 14 SEER efficiency rating delivers solid energy savings without ENERGY STAR premium cost
  • Multi-speed EEM blower motor optimizes comfort and reduces runtime cycling
  • R454B refrigerant provides future-proof operation under EPA regulations
  • Compact 35.5 x 35.5 x 38.25 inch footprint simplifies outdoor placement
  • 10-year warranty with online registration provides solid coverage confidence

Cons

  • 77 dBA noise level is noticeably louder than variable-stage competitors, affecting outdoor living space comfort
  • Single-stage compressor means less efficiency during partial-load conditions compared to two-stage models
  • Not ENERGY STAR certified, limiting eligibility for some utility rebates and tax incentives

Who Should Buy

Best For

Contractors installing replacement systems for customers in climates with significant heating demands will appreciate the 68,200 BTU output and straightforward single-stage design. Homeowners replacing 10-15 year old equipment and comfortable with standard noise levels should find the balance of performance, reliability, and value attractive.

Consider Alternatives If

Buyers in cold climates requiring frequent auxiliary heat, or those seeking ultra-quiet operation or top-tier efficiency ratings, should explore variable-capacity or two-stage alternatives.

Goodman 5 Ton 14 SEER Heat Pump Split System - R41
$0
Buy at HVACDirect →

Installation

Installation follows conventional split system protocols. Units accept 208, 230, or 240 volt single-phase power with 57-60 amp breaker sizing for Circuit 1 and 50 amp for Circuit 2. Liquid lines run 3/8 inch while suction lines measure 1 1/8 inch with included 1/2 inch insulation. The compact 120-pound weight aids handling. Pre-evacuation and proper refrigerant charge remain critical for optimal efficiency and longevity.

Warranty & Reliability

Goodman's 10-year parts warranty activates through online registration, protecting against manufacturing defects across compressor, coil, and electrical components. This duration meets industry standards and provides solid peace of mind for residential applications. Registration is straightforward and recommended immediately after installation to document coverage start dates.

Specifications

SKUACIQ-60-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU57,000
Heating BTU68,200
RefrigerantR454B
Electrical208 / 230 / 240 Volts / 1 Phase
Warranty10 Years with Online Registration
Decibel Level (dBA)77
Weight (in lbs)120.000000
FeatureSpec
Blower MotorMulti Speed - EEM
Maximum CFM2,265
Electric Backup Heat Capabilities (Optional)5 Kilowatts, 8 Kilowatts, 10 Kilowatts, 15 Kilowatts, 20 Kilowatts
Filter Size23" x 20"
Liquid Line3/8"
Suction Line1 1/8"
Max Breaker SizeCircuit 1: 60 amps / Circuit 2: 50 amps
Min. Breaker SizeCircuit 1: 57 amps / Circuit 2: 50 amps
Tonnage5 Ton
Fuel TypeElectric
Height38.25"
Width35.5"
Depth35.5"
ResourcesGoodman Installation Manual Goodman Specifications Goodman Parts Manual Goodman Service Manual Goodman Kit Installation Manual You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ReplacesGSZ140611
Energy StarNo
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Valve TypeSweat
Suction Line Insulation Thickness1/2"
Length50 feet
Electric Heat20 Kilowatts
PhaseSingle Phase

Frequently Asked Questions

What refrigerant does this unit use and why does it matter? +
This system uses R454B, a low-GWP refrigerant replacing older R410A. R454B complies with EPA Phase-down regulations and won't face future availability restrictions. It requires proper handling during service but offers identical cooling and heating performance to standard refrigerants in this equipment class.
Can I add electric backup heat, and what are my options? +
Yes. This unit supports optional electric resistance heating in 5, 8, 10, 15, or 20 kilowatt configurations. The included 20 kW option provides robust backup heating for cold climates. Electric heat activation ensures reliable operation when outdoor temperatures prevent efficient heat pump cycling.
How does the 14 SEER rating compare to newer standards? +
SEER1 (14) rates seasonal efficiency under older test conditions. Modern SEER2 ratings run approximately 20-25% lower, meaning this unit performs better than its 14 rating suggests under real-world conditions. It delivers respectable efficiency without ENERGY STAR premium costs.
Is single-stage operation a disadvantage versus two-stage systems? +
Single-stage means the compressor runs full-capacity or off, missing partial-load efficiency gains available in two-stage units. For average properties, performance difference remains modest. Two-stage units excel in variable climate regions experiencing significant temperature swings during heating and cooling seasons.
What does the 10-year warranty actually cover? +
Coverage includes parts defects for compressor, coil, and electrical components. Labor and refrigerant are typically excluded under standard terms. Register online immediately after installation to activate coverage and document service history for potential claims.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.