Review
The Mitsubishi MSZ-GS24NA represents the 24,000 BTU indoor unit within Mitsubishi's quad zone H2i Hyper Heat system. This wall-mounted mini split targets homeowners and contractors who need serious heating performance in cold climates alongside efficient cooling capacity. At 23 SEER2 and 11 HSPF, the unit balances year-round capability with legitimate efficiency credentials that satisfy modern energy codes and utility rebate programs.
This unit produces 27,600 BTU heating output and 22,400 BTU cooling capacity, paired with an 11 HSPF heating efficiency rating that meaningfully outperforms conventional 9 HSPF systems. The 15 EER cooling rating and 23 SEER2 efficiency ensure summer performance doesn't suffer despite the heating focus. Hyper Heat technology maintains output during extreme cold snaps, while CFM ranges of 336 to 701 heating and 361 to 701 cooling provide variable speed operation for part-load efficiency.
Pros & Cons
Pros
- 11 HSPF heating efficiency is exceptional for cold climate performance, delivering 27,600 BTU of heating output
- 23 SEER2 cooling efficiency with 15 EER means strong performance in warm months without sacrificing winter capability
- Hyper Heat technology maintains heating output at temperatures other systems struggle, making it practical for Maine, Minnesota, or upstate New York winters
- Quad zone (6+6+6+24) flexibility allows independent temperature control across four separate rooms or areas without installing four separate systems
- 10 year warranty with online registration provides legitimate peace of mind for a $0 product requiring significant installation investment
Cons
- 50 amp amperage requirement demands qualified electrician assessment, adding installation complexity and potential cost
- Multi-zone wall-mounted units require running refrigerant lines and electrical to four separate locations, making retrofit installations labor intensive
- 34 to 53 dBA cooling noise range means the outdoor compressor audible from neighboring properties in quiet suburban settings
Who Should Buy
Best For
Contractors and homeowners in cold climates installing new construction or major HVAC renovations where four zones justify the infrastructure investment. This system works best for homes larger than 2,500 square feet where independent zone control meaningfully reduces heating waste.
Consider Alternatives If
Budget-conscious buyers seeking simple two-zone solutions, or anyone in mild climates where standard 9 HSPF heat pumps adequately handle winters without specialized Hyper Heat technology.
Installation
Installation requires 208/230v single phase 60 Hz service with 40 to 45 amp breaker capacity and 50 amp wire sizing. Four separate wall-mounted indoor units need individual refrigerant lines (1/4 inch liquid, 5/8 inch suction), electrical connections, and drainage (5/8 inch line). Wireless controller simplifies setup. Most installations demand licensed HVAC technician with mini split experience and EPA certification.
Warranty & Reliability
Mitsubishi provides 10 year full coverage with online registration, protecting against manufacturing defects across compressor, controls, and components. This warranty covers parts and labor but excludes normal wear, refrigerant loss from leaks, or installation errors. Registration is straightforward and recommended immediately after commissioning.
Specifications
| SKU | MSZ-GS24NA |
| Brand/Manufacturer | Mitsubishi |
| Cooling BTU | 22,400 BTU |
| Heating BTU | 27,600 BTU |
| Refrigerant | R410A |
| Electrical | 208/230v 1 Phase 60 Hz |
| BTU/Tonnage | 24,000 BTU/2 Ton |
| Mini Split Type | Wall Mounted |
| Zone Compatibility | Multi Zone |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | C: 34-53 & H: 32-52 |
| Weight (in lbs) | 37.000000 |
| Feature | Spec |
| Replaces | MXZ-SM36NAMHZ |
| Product Features | Hyper Heat |
| HSPF | 11 |
| SEER2 (Efficiency) | 23 |
| EER | 15 |
| Liquid Line | 1/4" |
| Suction Line | 5/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 40 amps |
| Amperage Requirement | 50 |
| Height | 12-13/16" |
| Width | 43-5/16" |
| Depth | 9-3/8" |
| Resources | Submittal Service Manual Parts Manual Operation Manual Installation Manual Engineering Data You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Controller | Wireless Included |
| Additional Information | Drain: 5/8" |
| Maximum CFM | C: 361-701 & H: 336-701 |
| Capacity | Dehumidification Rate: 0.77 gal/hr |
| Operating Mode | Cooling, Heating |
| Phase | Single Phase |