Review
The Mitsubishi 36,000 BTU quad-zone heat pump system represents a practical middle ground in the mini-split market. This wall-mounted configuration delivers 36,000 BTU cooling and 42,000 BTU heating across four independently controlled zones, making it suitable for homes where traditional central HVAC proves impractical. The 19.2 SEER rating positions it within the high-efficiency bracket, though it misses ENERGY STAR certification despite competitive specifications. Online Supply's offering includes wireless control as standard, eliminating hidden accessory costs.
Performance metrics show balanced engineering. The SEER1 efficiency rating of 23 and EER of 15 indicate strong cooling performance, while the HSPF range of 12.5-11.2 provides solid heating output. Maximum CFM ranges from 109 to 406, offering flexibility from quiet operation to aggressive conditioning. The system handles dehumidification at 0.23 gallons per hour, helpful in humid climates. Operating between 14 and 115 degrees for cooling and 5 to 65 degrees for heating covers most U.S. climates, though northern regions experience seasonal heating limitations.
Pros & Cons
Pros
- SEER1 rating of 23 and HSPF of 12.5-11.2 deliver strong efficiency in both cooling and heating cycles
- Quad-zone configuration (9+9+12+12 BTU split) allows precise room-by-room temperature management
- 42,000 BTU heating capacity exceeds cooling capacity, beneficial for cold climates
- Maximum 492-foot line length supports flexible installation in larger homes
- Wireless controller included, eliminating additional control costs
Cons
- Not ENERGY STAR certified despite high SEER rating, which may limit utility rebate eligibility
- Heating limited to 5-65 degree outdoor temperatures, restricting performance in extreme cold regions
- 5-year parts warranty is standard but shorter than premium competitors offering 10-year coverage
- Wall-mounted units require visible installation in each zone, creating aesthetic compromises in finished spaces
Who Should Buy
Best For
Contractors installing systems for customers with four distinct zones in homes up to 3,600 square feet who want efficient independent control. Homeowners in temperate to moderate climates who need both strong cooling and heating and can accommodate wall-mounted indoor units.
Consider Alternatives If
Buyers in extreme cold climates below 5 degrees, those prioritizing ENERGY STAR rebates, or anyone needing hidden/concealed ductwork solutions should evaluate alternatives.
Installation
Installation requires 208/230V single-phase power with 30-40 amp breaker capacity. The system uses standard R410A refrigerant with 3/8-inch liquid and 5/8-inch suction lines. The 492-foot maximum line length accommodates larger homes and complex layouts. Wall-mounted indoor units measure 38 inches wide by 3 inches deep, demanding visible wall space in each zone. A surge protector install guide is provided, though professional HVAC installation remains strongly recommended for proper refrigerant charging and electrical work.
Warranty & Reliability
The 5-year parts warranty covers manufacturing defects on all components. This aligns with industry standard coverage but trails premium manufacturers offering 10-year extended protection. Coverage applies to genuine part failures but typically excludes labor, installation issues, and damage from improper maintenance. Homeowners should register equipment promptly and maintain service records to ensure claim eligibility.
Specifications
| SKU | 87762 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 36,000 |
| Heating BTU | 42,000 |
| Refrigerant | R410A |
| Electrical | 208/230V 1 Phase 60 Hz |
| BTU/Tonnage | 36,000 BTU/3 Ton |
| Mini Split Type | Wall Mounted |
| Zone Compatibility | Multi Zone |
| Warranty | 5 Years Parts Warranty |
| Decibel Level (dBA) | 53 |
| Weight (in lbs) | 5.000000 |
| Feature | Spec |
| Controller | Wireless Included |
| Additional Information | Maximum System Line Length: 492' |
| Maximum CFM | 109-406 CFM |
| Capacity | Dehumidification Rate: 0.23 gal/hr |
| Liquid Line | 3/8" |
| Suction Line | 5/8" |
| Operating Mode | Cooling, Heating |
| Height | 3" |
| Width | 18" |
| Depth | 38" |
| Resources | Surge Protector Install Guide You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Phase | Single Phase |
| Energy Star | No |
| HSPF | 12.5-11.2 |
| SEER1 (Efficiency) | 23 |
| EER | 15 |
| Max Breaker Size | 40 |
| Min. Breaker Size | 30 |
| Tonnage | 3 Ton |
| Min/Max Outdoor Temp for Heating | 5°-65° |
| Min/Max Outdoor Temp for Cooling | 14°-115° |
| Length | 15' |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.