Review
The Mitsubishi 36,000 BTU quad-zone heat pump targets the contractor and serious DIY market segment where efficiency meets multi-room flexibility. Positioned as a mid-to-premium option, this system combines modern mini-split convenience with four independent zone control. The wireless controller inclusion and Online Supply's distribution make it accessible to both professional installers and experienced homeowners seeking better climate management than traditional single-zone equipment provides.
Performance specs are genuinely strong here. The 19.2 SEER rating substantially outperforms industry baseline 14 SEER equipment, translating to roughly 35-40% lower cooling costs over a season. Heating efficiency reaches 12.5 HSPF at optimal conditions, though that drops to 11.2 in colder weather. The 36,000 BTU cooling capacity pairs with 42,000 BTU heating, creating slight heating bias useful for northern applications. EER rating of 15 indicates solid part-load efficiency, and the 53 dB sound level keeps operations unobtrusive in occupied spaces.
Pros & Cons
Pros
- 19.2 SEER efficiency rating delivers substantial energy savings compared to standard 14-16 SEER systems
- 36,000 BTU cooling and 42,000 BTU heating capacity handles moderate-sized multi-zone applications
- Wireless controller included, eliminating extra expense and simplifying zone management
- Maximum 492-foot line length accommodates larger installations without refrigerant line penalties
- Quiet operation at 53 dB, comparable to residential AC window units
- R410A refrigerant is industry standard with good availability and established service infrastructure
Cons
- One-year full replacement warranty is shorter than typical 5-10 year manufacturer coverage on comparable systems
- SEER1 rating of 23 listed in specs conflicts with advertised 19.2 SEER, creating specification clarity issues
- No Energy Star certification despite high efficiency claims, raising questions about third-party verification
- Limited outdoor heating range of 5-65 degrees restricts use in severely cold climates
Who Should Buy
Best For
This system suits contractors completing retrofit projects in moderate climates where four separate zones justify the added complexity and cost. Homeowners with 3,000-4,000 square foot homes wanting efficient zone control and willing to handle straightforward installation will appreciate the wireless controller and strong SEER performance.
Consider Alternatives If
Skip this if you need extended warranty protection, live in climates regularly below 5 degrees, or prefer single-zone simplicity over multi-zone management.
Installation
Installation requires standard HVAC knowledge, though the quad-zone configuration adds complexity versus single-zone systems. The 492-foot maximum line length provides substantial flexibility for larger homes. Refrigerant lines use 3/8-inch liquid and 5/8-inch suction sizing, standard for 3-ton applications. Wall-mounted indoor units mount easily, and the included wireless controller eliminates thermostat wiring labor. A 30-40 amp breaker is required depending on circuit configuration.
Warranty & Reliability
The one-year full replacement warranty provides basic protection against manufacturing defects but falls significantly short of industry-standard five-year warranties on comparable systems. This limits your coverage as components age, making extended service agreements worth evaluating. Replacement parts sourced through Online Supply should remain available during the warranty period, though long-term parts availability remains uncertain for non-major brands.
Specifications
| SKU | 87762 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 36,000 |
| Heating BTU | 42,000 |
| Refrigerant | R410A |
| Electrical | Micro USB with Standard Plug |
| BTU/Tonnage | 36,000 BTU/3 Ton |
| Mini Split Type | Wall Mounted |
| Zone Compatibility | Multi Zone |
| Warranty | 1 Year Full Replacement |
| Decibel Level (dBA) | 53 |
| Weight (in lbs) | 5.000000 |
| Feature | Spec |
| Controller | Wireless Included |
| Additional Information | Maximum System Line Length: 492' |
| Maximum CFM | C: 191-504 & H: 191-437 |
| Capacity | Dehumidification Rate: 0.41 gal/hr |
| Liquid Line | 3/8" |
| Suction Line | 5/8" |
| Operating Mode | Cooling, Heating |
| Height | 3" |
| Width | 18" |
| Depth | 38" |
| Resources | Surge Protector Install Guide You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Phase | Single Phase |
| Energy Star | No |
| HSPF | 12.5-11.2 |
| SEER1 (Efficiency) | 23 |
| EER | 15 |
| Max Breaker Size | 40 |
| Min. Breaker Size | 30 |
| Tonnage | 3 Ton |
| Min/Max Outdoor Temp for Heating | 5°-65° |
| Min/Max Outdoor Temp for Cooling | 14°-115° |
| Length | 30' |