Review
The Mitsubishi H2i five-zone heat pump system positions itself at the premium end of the ductless multi-split market. This 42,000 BTU cooling unit targets contractors and homeowners seeking granular temperature control across multiple zones simultaneously. With Hyper Heat technology and a 21.5 SEER2 efficiency rating, it combines advanced heating capability with exceptional cooling performance. The 6+6+6+6+12 zone configuration allows installers to tailor capacity distribution to specific project layouts, making it flexible for both residential renovations and new construction applications.
Efficiency metrics here are genuinely impressive. The 21.5 SEER2 rating translates to lower monthly cooling bills, while the 13.4 EER indicates strong performance at peak summer loads. On the heating side, 32,000 BTU output with Hyper Heat technology means this system won't default to backup electric resistance during cold snaps, a critical feature for northern climates. The 42,000 BTU cooling capacity handles a 3.5-ton cooling load, while 109-399 CFM airflow flexibility lets you match different room sizes and installation constraints effectively.
Pros & Cons
Pros
- 21.5 SEER2 rating provides top-tier cooling efficiency and lower operating costs year-round
- Hyper Heat technology maintains heating output down to extreme cold temperatures, rated at 32,000 BTU heating capacity
- Five independent zones with 6+6+6+6+12 configuration allows customized comfort in different rooms simultaneously
- Wireless controller included, eliminating additional installation expenses
- Single-phase 230V electrical requirement simplifies retrofit compatibility in most residential settings
- Ultra-quiet operation ranging from 19-45 dB across settings, suitable for bedrooms and living areas
Cons
- Specifications contain data inconsistencies, particularly height and width listed as 0.5 inches each, raising questions about actual unit dimensions
- No visible pricing information makes budget planning difficult for contractors requesting quotes
- Five-zone configuration requires extensive ductwork and refrigerant line runs, increasing installation complexity and labor costs significantly
Who Should Buy
Best For
Contractors tackling multi-room renovation projects in cold climates where zone flexibility matters, and homeowners needing simultaneous heating and cooling across five separate spaces. This system excels in homes where traditional central HVAC can't efficiently serve disparate temperature needs.
Consider Alternatives If
Budget-conscious buyers should explore single or two-zone alternatives, as the five-zone configuration adds substantial installation expense. Those in mild climates won't justify the premium Hyper Heat technology cost.
Installation
This system demands careful planning. The 15-foot refrigerant line length, combined with 3/8-inch liquid and 5/8-inch suction lines, requires trenching or wall chasing between outdoor and indoor units. Five separate zone heads mean five separate line sets and electrical connections. Single-phase 230V at 50 amps keeps electrical demands reasonable compared to three-phase alternatives, but breaker sizing between 40-45 amps still requires dedicated circuits. Professional installation is strongly recommended.
Warranty & Reliability
A five-year parts warranty covers manufacturing defects across compressors, circuit boards, and coils. This is standard for Mitsubishi products but doesn't include labor or refrigerant. For contractors, registering units immediately protects against warranty disputes. Homeowners should clarify whether their installer provides additional labor coverage beyond the manufacturer's parts guarantee.
Specifications
| SKU | 201813 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 42,000 |
| Heating BTU | 32,000 |
| Refrigerant | R410A |
| Electrical | 230 V. 1 Phase 60 Hz |
| BTU/Tonnage | 42,000 BTU/3.5 Ton |
| Mini Split Type | Wall Mounted |
| Zone Compatibility | Multi Zone |
| Warranty | 5 Years Parts Warranty |
| Decibel Level (dBA) | 19-45 |
| Weight (in lbs) | 15.000000 |
| Feature | Spec |
| Controller | Wireless Included |
| Additional Information | Drain: 5/8" |
| Maximum CFM | 109-399 CFM |
| Capacity | Dehumidification Rate: 0.38 gal/hr |
| Liquid Line | 3/8" |
| Suction Line | 5/8" |
| Operating Mode | Cooling, Heating |
| Height | 1/2" |
| Width | 1/2" |
| Depth | 38" |
| Resources | HW-600 Install Guide You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Phase | Single Phase |
| Replaces | MXZ-5C42NAHZ2 |
| Product Features | Hyper Heat |
| SEER2 (Efficiency) | 21.5 |
| EER | 13.4 |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 40 |
| Amperage Requirement | 50 |
| Length | 15' |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.