The Mitsubishi 42,000 BTU Quad Zone H2i represents a capable entry into the premium mini-split market. This wall-mounted system splits capacity across four independent zones, allowing contractors and homeowners to achieve granular temperature control without the expense and disruption of traditional ductwork. With a SEER2 rating of 21.5, it positions itself as an efficiency-focused choice for residential applications seeking lower operating costs and modern performance.
Performance data reveals solid all-around capabilities. The 42,000 BTU cooling capacity with 19 SEER efficiency delivers reliable climate management for medium to large spaces. Heating output reaches 32,000 BTU, providing adequate warmth in moderate winters, though cold-climate users should note this trails cooling capacity by 10,000 BTU. CFM ranges from 191 to 504 for cooling and 191 to 437 for heating, with sound levels between 26 and 49 dB during operation. The EER rating of 13.4 indicates strong cooling efficiency under peak load conditions.
Pros & Cons
Pros
- SEER2 rating of 21.5 delivers superior cooling efficiency compared to standard 19 SEER systems, reducing operating costs
- Quad-zone configuration (6, 12, 12, 15 ton split) allows independent temperature control in up to four separate rooms or zones
- Hyper Heat technology maintains effective heating down to extreme cold temperatures, crucial for northern climates
- 42,000 BTU cooling capacity handles larger residential spaces that single-zone systems cannot manage
- Wireless controller included with installation, eliminating additional control system costs
- Single-phase 230V electrical requirement simplifies installation on standard residential service
Cons
- 30-foot refrigerant line length limits flexibility in home layout and may require additional line sets for some installations
- Heating capacity of 32,000 BTU trails cooling capacity by 10,000 BTU, which may underwhelm in severe winter climates despite Hyper Heat rating
- 5-year parts warranty is shorter than some competing Mitsubishi models offering 10-year coverage
Who Should Buy
Best For
Homeowners with multi-room homes or room additions who need zoned temperature control without adding ductwork should seriously consider this system. It's ideal for properties with 3-4 distinct climate zones where central air is impractical or impossible to install.
Consider Alternatives If
Buyers in extreme cold climates who need heating capacity equal to or exceeding cooling capacity should explore models with higher BTU heating ratings, as the 32,000 BTU heating spec may limit winter performance despite Hyper Heat technology.
Installation
Installation requires 230V single-phase 60Hz service with a 40 to 45 amp breaker, straightforward for most homes. The system needs refrigerant lines (3/8 inch liquid, 5/8 inch suction) and a 5/8 inch drain line. Standard wall-mounted placement suits most interior layouts, though the 30-foot line length may constrain installation flexibility in larger homes or complex configurations requiring extended runs.
Warranty & Reliability
Mitsubishi backs this system with a 5-year parts warranty, covering component failures and defects. This standard coverage protects against manufacturing issues but falls short of extended warranties some competitors offer. Homeowners should budget for potential repair costs after year five, though Mitsubishi units generally maintain reliability beyond the warranty period.
Specifications
| SKU | 216740 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 42,000 |
| Heating BTU | 32,000 |
| Refrigerant | R410A |
| Electrical | 230 V. 1 Phase 60 Hz |
| BTU/Tonnage | 42,000 BTU/3.5 Ton |
| Mini Split Type | Wall Mounted |
| Zone Compatibility | Multi Zone |
| Warranty | 5 Years Parts Warranty |
| Decibel Level (dBA) | C: 26-49 & H: 26-46 |
| Weight (in lbs) | 30.000000 |
| Feature | Spec |
| Controller | Wireless Included |
| Additional Information | Drain: 5/8" |
| Maximum CFM | C: 191-504 & H: 191-437 |
| Capacity | Dehumidification Rate: 0.41 gal/hr |
| Liquid Line | 3/8" |
| Suction Line | 5/8" |
| Operating Mode | Cooling, Heating |
| Height | 1/2" |
| Width | 1/2" |
| Depth | 38" |
| Resources | Surge Protector Install Guide You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Phase | Single Phase |
| Replaces | MXZ-5C42NAHZ2 |
| Product Features | Hyper Heat |
| SEER2 (Efficiency) | 21.5 |
| EER | 13.4 |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 40 |
| Amperage Requirement | 50 |
| Length | 30' |
Frequently Asked Questions